Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Influence of installing a virtual synchronous generator control on Lombok Island power grid with high penetration of PV plants

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 6 (2025) · hlm. 4279–4289

DOI
10.11591/eei.v14i6.9733
ISSN
2089-3191, 2302-9285
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Indonesia is a country with several islands, and providing clean energy in islanded power systems connected to a single main grid would be economy challenging. On the other hand, absence of inertia, system strength, and damping value in islanded power systems due to inverter interfaced renewable energy (RE) resources can cause significant decline of power system stability. The primary concern with integrating large scale photovoltaic (PV) power plant in an islanded power system is maintaining frequency and voltage stability. This research investigates the application of virtual synchronous generator (VSG) in Lombok’s Islanded power system, considering high penetration of PV. A thorough time domain simulation is performed with a detailed modelling of power system in Lombok Island to study the dynamic voltage and frequency stability. The simulation results show that the VSG improves both frequency and voltage stability in transient and steady state stages, ensuring smoother operation and faster stabilization time. It is found that the frequency deviation can be curtail up to 0.5% and the steady state can be increased up to 0.1%.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 156 tautan kepenulisan bersama · 76 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universitas Pertamina
  • Telkom University
  • The University of Queensland
  • Institut Teknologi Sepuluh Nopember
  • SRM Institute of Science and Technology
  • Institut Teknologi Nasional Bandung
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad AbdillahUniversitas Pertamina12
Prisma MegantoroUniversitas Airlangga5
Rezi DelfiantiUniversitas Airlangga5
Lilik Jamilatul AwalinUniversitas Airlangga3
P. VigneshwaranSRM Institute of Science and Technology3
Nita Indriani PertiwiUniversitas Pertamina3
Senit Araminta JasmineUniversitas Airlangga3
Teguh Aryo NugrohoUniversitas Pertamina2
Hafidz Faqih Aldi KusumaUniversitas Airlangga2
Awan Uji KrismantoInstitut Teknologi Nasional Bandung2
Tirta JayadiharjaUniversitas Pertamina2
R. Harry ArjadiIndonesian Institute of Sciences2
Ramon ZamoraAuckland University of Technology2
Sigit Dani PerkasaUniversitas Airlangga2
Muhammad Akbar SyahbaniUniversitas Airlangga2
Abdul AbrorUniversitas Airlangga2
Alfi SolehanUniversitas Pertamina2
Karl O. JonesLiverpool John Moores University1
Herri TrilaksanaUniversitas Airlangga1
Tahta AmrillahUniversitas Airlangga1
Brahmantya Aji PramuditaTelkom University1
Dimas Febriyan PriambodoPoliteknik Siber dan Sandi Negara1
Muhammad Zakiyullah RomdlonyTelkom University1
Alwy Muhammad RaviTelkom University1
Fakhruddin ArraziAfiliasi tidak diketahui1
Bima MustaqimInstitut Teknologi Sepuluh Nopember1
Fidya Eka PrahestiUniversitas Nusantara PGRI Kediri1
Bolas Boy SilalahiInstitut Teknologi Sepuluh Nopember1
Antik Widi AnugrahUniversitas Airlangga1
Sinta Adisti ReinaUniversitas Airlangga1
Agus MukhlisinUniversitas Airlangga1
Ahmad Rahmad MuzadiUniversitas Airlangga1
Arie Bagus LaksonoUniversitas Pertamina1
Naufal Evanda PutraUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Influence of installing a virtual synchronous generator control on Lombok Island power grid with high penetration of PV plants</dc:title><dc:creator>Herlambang Setiadi</dc:creator><dc:creator>N. Mithulananthan</dc:creator><dc:creator>Baity Nuris Syifa</dc:creator><dc:creator>Yoshiko Ricky Ananda</dc:creator><dc:creator>Riski Cahya Anugrerah Haebibi</dc:creator><dc:creator>Yusrizal Afif</dc:creator><dc:subject>virtual synchronous generator</dc:subject><dc:subject>islanded power systems</dc:subject><dc:subject>photovoltaic penetration</dc:subject><dc:subject>frequency stability</dc:subject><dc:subject>voltage stability</dc:subject><dc:subject>time-domain simulation</dc:subject><dc:description xml:lang="en">Indonesia is a country with several islands, and providing clean energy in islanded power systems connected to a single main grid would be economy challenging. On the other hand, absence of inertia, system strength, and damping value in islanded power systems due to inverter interfaced renewable energy (RE) resources can cause significant decline of power system stability. The primary concern with integrating large scale photovoltaic (PV) power plant in an islanded power system is maintaining frequency and voltage stability. This research investigates the application of virtual synchronous generator (VSG) in Lombok’s Islanded power system, considering high penetration of PV. A thorough time domain simulation is performed with a detailed modelling of power system in Lombok Island to study the dynamic voltage and frequency stability. The simulation results show that the VSG improves both frequency and voltage stability in transient and steady state stages, ensuring smoother operation and faster stabilization time. It is found that the frequency deviation can be curtail up to 0.5% and the steady state can be increased up to 0.1%.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i6.9733</dc:identifier><dc:identifier>10.11591/eei.v14i6.9733</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 6 (2025); 4279-4289</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9733/4453</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>