Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Parameters affecting protection coordination of high voltage distribution network with distributed energy resources

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 2 (2026) · hlm. 986–998

DOI
10.11591/eei.v15i2.10045
ISSN
2089-3191, 2302-9285
Terbit
2026-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Distributed energy resources (DERs) have become favorable sources of power against conventional power sources at distribution level because of their advantages like reduction in power loss and voltage drop, and environment friendliness. Integrating of DERs into high voltage distribution networks (HVDNs) introduces significant challenges to protection relay coordination because of their dynamic operational characteristics. This comprehensive study investigates key parameters influencing effective protection relay coordination in distribution networks (DNs), including fault current variability, DER penetration level, network topology, and relay settings. Through comprehensive simulation conducted on modified IEEE 4-bus HVDN with variable DER configurations through PSCAD/EMTDC 4.5 software, the research analysis evaluates the impact of these parameters on protection reliability and speed. Results indicate that high DER penetration leads to fault current increment by 10-20%, grid current contribution reduction by 10-15% as well as relay current setting alterations approximately by 30-40% which necessitates adaptive protection schemes. Network topology and relay coordination strategy significantly affect fault detection and isolation process. The finding provides understanding of parameters affecting protection coordination which helps in its optimization and having reliable and secure operation of DN.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Gujarat Technological University
  • Pandit Deendayal Energy University
  • Hamad Medical Corporation
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Parameters affecting protection coordination of high voltage distribution network with distributed energy resources</dc:title><dc:creator>Ishan Desai</dc:creator><dc:creator>Nilesh Chothani</dc:creator><dc:creator>Paul Jacob</dc:creator><dc:subject>relay coordination</dc:subject><dc:subject>high-voltage distribution networks</dc:subject><dc:subject>distributed energy resources</dc:subject><dc:subject>network topology</dc:subject><dc:subject>fault detection and isolation</dc:subject><dc:subject>adaptive protection</dc:subject><dc:subject>protection reliability</dc:subject><dc:description xml:lang="en">Distributed energy resources (DERs) have become favorable sources of power against conventional power sources at distribution level because of their advantages like reduction in power loss and voltage drop, and environment friendliness. Integrating of DERs into high voltage distribution networks (HVDNs) introduces significant challenges to protection relay coordination because of their dynamic operational characteristics. This comprehensive study investigates key parameters influencing effective protection relay coordination in distribution networks (DNs), including fault current variability, DER penetration level, network topology, and relay settings. Through comprehensive simulation conducted on modified IEEE 4-bus HVDN with variable DER configurations through PSCAD/EMTDC 4.5 software, the research analysis evaluates the impact of these parameters on protection reliability and speed. Results indicate that high DER penetration leads to fault current increment by 10-20%, grid current contribution reduction by 10-15% as well as relay current setting alterations approximately by 30-40% which necessitates adaptive protection schemes. Network topology and relay coordination strategy significantly affect fault detection and isolation process. The finding provides understanding of parameters affecting protection coordination which helps in its optimization and having reliable and secure operation of DN.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i2.10045</dc:identifier><dc:identifier>10.11591/eei.v15i2.10045</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 2 (2026); 986-998</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10045/4684</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>