Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Empowering energy management: anomaly detection in smart meter data for proactive consumption control

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 3 (2026) · hlm. 2712–2733

DOI
10.11591/eei.v15i3.10957
ISSN
2089-3191, 2302-9285
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The increasing deployment of smart energy meters (SEMs) has enabled real-time monitoring of energy consumption, but the vast data generated makes it challenging to detect anomalies that may indicate inefficiencies, faults, or unauthorized usage. This study aims to enhance energy management by developing a hybrid anomaly detection framework that improves accuracy while providing actionable insights for consumers. The proposed method integrates statistical and machine learning (ML) approaches, specifically Z-score, local outlier factor (LOF), one-class support vector machine (SVM), and isolation forest (iForest), to analyze simulated smart meter data. An anomaly is flagged only when identified by all four methods, thereby reducing false positives and improving reliability. The framework is implemented in an interactive dashboard built with streamlit, offering real-time visualization, peak-time alerts, usage forecasts, and personalized consumption suggestions. Results demonstrate that the hybrid approach outperforms single-method models, achieving higher detection accuracy and practical applicability. The findings highlight the potential of combining complementary detection techniques with proactive feedback to empower consumers, reduce energy wastage, and support sustainable energy management. This work provides a scalable foundation for future real-time deployment in smart grids and microgrid environments.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 174 tautan kepenulisan bersama · 38 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Jawaharlal Nehru Technological University, Hyderabad
  • Applied Science Private University
  • Vardhaman College of Engineering
  • Amrita Vishwa Vidyapeetham
  • Prasad V. Potluri Siddhartha Institute of Technology
  • Maharaj Vijayaram Gajapathi Raj College of Engineering
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rakesh TeerdalaJawaharlal Nehru Technological University, Hyderabad11
Srungaram Ravi TejaKoneru Lakshmaiah Education Foundation10
Ravi PonnalaKoneru Lakshmaiah Education Foundation10
Thulasi BikkuAmrita Vishwa Vidyapeetham8
Ganapaneni SwapnaKoneru Lakshmaiah Education Foundation7
Thalanki Venkata Sai KalyaniAfiliasi tidak diketahui6
Mareboyina Karthik YadavKoneru Lakshmaiah Education Foundation6
Putta Dhanush NarasimhaKoneru Lakshmaiah Education Foundation6
Tellapati Anuradha DeviVardhaman College of Engineering4
Guttikonda Chandra BabuKoneru Lakshmaiah Education Foundation4
Patil MounikaAfiliasi tidak diketahui4
Chilakala Rami ReddyAfiliasi tidak diketahui4
E. Shiva PrasadAfiliasi tidak diketahui4
Enukonda SoumyaAfiliasi tidak diketahui4
M.Venugopala RaoAfiliasi tidak diketahui2
K. Harinadha ReddyKoneru Lakshmaiah Education Foundation2
Bodapati Venkata RajannaKoneru Lakshmaiah Education Foundation2
D. Ravi KumarJawaharlal Nehru Technological University, Hyderabad2
Manne BharathiVignan's Foundation for Science, Technology & Research2
I. S. N. V. R. PrasanthAfiliasi tidak diketahui2
M. Venu Gopala RaoPrasad V. Potluri Siddhartha Institute of Technology1
Mudundi RekhaKoneru Lakshmaiah Education Foundation1
Anuradha Devi TellapatiKoneru Lakshmaiah Education Foundation1
Venu YarlagaddaAfiliasi tidak diketahui1
N. KavithaMaharaj Vijayaram Gajapathi Raj College of Engineering1
Chava Sunil KumarAfiliasi tidak diketahui1
G NaveenNarasaraopeta Engineering College1
Swetha MareddyAfiliasi tidak diketahui1
S. Venkata Rami ReddyJawaharlal Nehru Technological University Anantapur1
M. LavanyaKoneru Lakshmaiah Education Foundation1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Empowering energy management: anomaly detection in smart meter data for proactive consumption control</dc:title><dc:creator>B. Jyothi</dc:creator><dc:creator>Bhavana Pabbuleti</dc:creator><dc:creator>Beeravalli Mounika</dc:creator><dc:creator>Hrushitha Kalapala</dc:creator><dc:creator>Meda Uma Santhosh Chandra</dc:creator><dc:creator>Singagari Srilakshmi</dc:creator><dc:creator>B. Ganesh Babu</dc:creator><dc:creator>Kambhampati Venkata Govardhan Rao</dc:creator><dc:creator>Malligunta Kiran Kumar</dc:creator><dc:creator>Ch. Rami Reddy</dc:creator><dc:subject>smart meter data</dc:subject><dc:subject>anomaly detection</dc:subject><dc:subject>energy management</dc:subject><dc:subject>hybrid anomaly detection</dc:subject><dc:subject>Z-score</dc:subject><dc:subject>local outlier factor</dc:subject><dc:subject>one-class support vector machine</dc:subject><dc:subject>Isolation Forest</dc:subject><dc:subject>energy consumption monitoring</dc:subject><dc:subject>smart grid</dc:subject><dc:subject>microgrids</dc:subject><dc:description xml:lang="en">The increasing deployment of smart energy meters (SEMs) has enabled real-time monitoring of energy consumption, but the vast data generated makes it challenging to detect anomalies that may indicate inefficiencies, faults, or unauthorized usage. This study aims to enhance energy management by developing a hybrid anomaly detection framework that improves accuracy while providing actionable insights for consumers. The proposed method integrates statistical and machine learning (ML) approaches, specifically Z-score, local outlier factor (LOF), one-class support vector machine (SVM), and isolation forest (iForest), to analyze simulated smart meter data. An anomaly is flagged only when identified by all four methods, thereby reducing false positives and improving reliability. The framework is implemented in an interactive dashboard built with streamlit, offering real-time visualization, peak-time alerts, usage forecasts, and personalized consumption suggestions. Results demonstrate that the hybrid approach outperforms single-method models, achieving higher detection accuracy and practical applicability. The findings highlight the potential of combining complementary detection techniques with proactive feedback to empower consumers, reduce energy wastage, and support sustainable energy management. This work provides a scalable foundation for future real-time deployment in smart grids and microgrid environments.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i3.10957</dc:identifier><dc:identifier>10.11591/eei.v15i3.10957</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 3 (2026); 2712-2733</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10957/4808</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>