Melola Discovery

← Melola Discovery

Jurnal SINTA 1

DFPI-based Control of the DC-bus Voltage and the AC-side Current of a Shunt Active Power Filter

Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 4 (2016) · hlm. 430–441

DOI
10.11591/eei.v5i4.572
ISSN
2089-3191, 2302-9285
Terbit
2016-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The current paper presents a continuation of an earlier research and purposes to enhance the performances of the studied system. While the double fuzzy PI (DFPI) control was applied only on the DC capacitor bus in a previous work it is applied here also on the output current of shunt active power filter (SAPF). The nonlinear load disrupts the electrical distribution system by the generation of harmonics, which requires an efficient SAPF intervention to minimize the effects of harmonics on the network and provide electrical energy conforms to international standards. The design and simulation of this work were performed under MATLAB/Simulink environment. The carried-out simulation results demonstrate a satisfactory regulation both for the output current of the SAPF and the DC bus voltage. Furthermore the power quality is improved since a near-unity power factor and very low rates of imbalance of both source voltages and currents are obtained.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université Ibn-Tofail
  • University Frères Mentouri Constantine 1
  • Research Center in Industrial Technologies
  • Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tarik JarouUniversité Ibn-Tofail3
Tariq BenamimourUniversity Frères Mentouri Constantine 11
Amar BentounsiUniversity Frères Mentouri Constantine 11
Azzedine BendiabdellahUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf1
Omar Fethi BenaoudaResearch Center in Industrial Technologies1
Mohamed MezaacheResearch Center in Industrial Technologies1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DFPI-based Control of the DC-bus Voltage and the AC-side Current of a Shunt Active Power Filter</dc:title><dc:creator>Nabil Elhaj</dc:creator><dc:creator>Moulay Brahim Sedra</dc:creator><dc:creator>Hind Djeghloud</dc:creator><dc:subject>shunt active power filter</dc:subject><dc:subject>DC bus voltage regulation</dc:subject><dc:subject>harmonic compensation</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>power quality</dc:subject><dc:subject>power factor correction</dc:subject><dc:description xml:lang="en">The current paper presents a continuation of an earlier research and purposes to enhance the performances of the studied system. While the double fuzzy PI (DFPI) control was applied only on the DC capacitor bus in a previous work it is applied here also on the output current of shunt active power filter (SAPF). The nonlinear load disrupts the electrical distribution system by the generation of harmonics, which requires an efficient SAPF intervention to minimize the effects of harmonics on the network and provide electrical energy conforms to international standards. The design and simulation of this work were performed under MATLAB/Simulink environment. The carried-out simulation results demonstrate a satisfactory regulation both for the output current of the SAPF and the DC bus voltage. Furthermore the power quality is improved since a near-unity power factor and very low rates of imbalance of both source voltages and currents are obtained.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v5i4.572</dc:identifier><dc:identifier>10.11591/eei.v5i4.572</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 4 (2016); 430-441</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/572/970</dc:relation></oai_dc:dc>