Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Decentralized proportional-integral control with carbon addition for wastewater treatment plant

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 6 (2020) · hlm. 2278–2285

DOI
10.11591/eei.v9i6.2170
ISSN
2089-3191, 2302-9285
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Two main challenges in activated sludge wastewater treatment plant (WWTP) are cost and effluent quality, which has forced the wastewater treatment operator to find an alternative to improve the existing control strategy. The Benchmark Simulation Model No. 1 (BSM1) is applied as operational settings for this study. In BSM1, the standard control variables are the internal recirculation flow rate and the oxygen transfer rate. To improve the existing control strategy of BSM1, three alternative control handles are proposed, which are the individual aeration intensity control, carbon source addition and combination of both. The effect of each control handles in terms of the effluent violation, effluent quality, aeration cost, and total operational cost index are examined. The simulation result has shown that the individual control of aeration intensity improved the effluent quality index, and reduced the aeration, pumping, and total operational cost index when compared to the standard BSM1 control handle. Nonetheless, the addition of a fixed external carbon source has shown a significantly improved effluent quality with a lower number of total nitrogen violations as compared to the standard BSM1 control handles. Thus, the proposed control handles may be beneficial if applied in a real WWTP.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 122 tautan kepenulisan bersama · 46 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Universiti Teknikal Malaysia Melaka
  • Universiti Malaysia Sarawak
  • Taibah University
  • Kano State University of Technology
  • Kuwait Institute for Scientific Research
  • Universiti Malaysia Perlis
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Syahira IbrahimUniversity of Technology Malaysia6
Ahmad Athif Mohd FaudziUniversity of Technology Malaysia3
Aznah Nor AnuarUniversity of Technology Malaysia3
Mashitah Che RazaliUniversity of Technology Malaysia3
Sy Najib Sy SalimUniversiti Teknikal Malaysia Melaka2
Mustafa M. BobTaibah University2
Khairuddin OsmanUniversiti Teknikal Malaysia Melaka2
Sharatul Izah SamsudinUniversiti Teknikal Malaysia Melaka2
Zakariah YusufUniversity of Technology Malaysia2
Nurazizah MahmodUniversity of Technology Malaysia2
Amar Faiz Zainal AbidinUniversiti Teknikal Malaysia Melaka2
Shafishuhaza SahlanUniversity of Technology Malaysia2
Muhammad Sani GayaKano State University of Technology2
Nur Sakinah Ahmad YasminUniversity of Technology Malaysia2
Zool Hilmi IsmailUniversity of Technology Malaysia1
Noorhazirah SunarUniversity of Technology Malaysia1
Shamsul Anuar SamsudinUniversiti Teknikal Malaysia Melaka1
Siti Fatimaah SulaimanAfiliasi tidak diketahui1
A. R. AziraUniversiti Teknikal Malaysia Melaka1
Abdallah AbusamKuwait Institute for Scientific Research1
Norjannah HazaliUniversity of Technology Malaysia1
Siti Marhainis OthmanUniversiti Malaysia Perlis1
Sahazati Md RozaliUniversiti Teknikal Malaysia Melaka1
Zulfatman HasUniversitas Muhammadiyah Malang1
Syed Najib Syed SalimUniversiti Teknikal Malaysia Melaka1
L. AbdullahUniversiti Teknikal Malaysia Melaka1
Shamsul Anuar ShamsudinUniversiti Teknikal Malaysia Melaka1
Maslan ZainonUniversiti Teknikal Malaysia Melaka1
A. F. M. AminAfiliasi tidak diketahui1
Siti Fatimah SulaimanUniversiti Teknikal Malaysia Melaka1
Noor Asyikin SulaimanUniversiti Teknikal Malaysia Melaka1
Parvaneh EsmailiAfiliasi tidak diketahui1
Aliyu Muhammad AbduUniversity of Technology Malaysia1
Sani Isah AbbaMaitama Sule University Kano1
Abubakar Ibrahim TukurAfiliasi tidak diketahui1
Mubarak Auwal SalehAfiliasi tidak diketahui1
Fatimah Sham IsmailUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Decentralized proportional-integral control with carbon addition for wastewater treatment plant</dc:title><dc:creator>Maimun Huja Husin</dc:creator><dc:creator>Mohd Fua’ad Rahmat</dc:creator><dc:creator>Norhaliza Abdul Wahab</dc:creator><dc:subject>decentralized control</dc:subject><dc:subject>PI controller</dc:subject><dc:subject>activated sludge</dc:subject><dc:subject>wastewater treatment plants</dc:subject><dc:subject>carbon source supplementation</dc:subject><dc:subject>effluent quality</dc:subject><dc:subject>operating costs</dc:subject><dc:subject>Benchmark Simulation Model No. 1</dc:subject><dc:description xml:lang="en">Two main challenges in activated sludge wastewater treatment plant (WWTP) are cost and effluent quality, which has forced the wastewater treatment operator to find an alternative to improve the existing control strategy. The Benchmark Simulation Model No. 1 (BSM1) is applied as operational settings for this study. In BSM1, the standard control variables are the internal recirculation flow rate and the oxygen transfer rate. To improve the existing control strategy of BSM1, three alternative control handles are proposed, which are the individual aeration intensity control, carbon source addition and combination of both. The effect of each control handles in terms of the effluent violation, effluent quality, aeration cost, and total operational cost index are examined. The simulation result has shown that the individual control of aeration intensity improved the effluent quality index, and reduced the aeration, pumping, and total operational cost index when compared to the standard BSM1 control handle. Nonetheless, the addition of a fixed external carbon source has shown a significantly improved effluent quality with a lower number of total nitrogen violations as compared to the standard BSM1 control handles. Thus, the proposed control handles may be beneficial if applied in a real WWTP.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i6.2170</dc:identifier><dc:identifier>10.11591/eei.v9i6.2170</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 6 (2020); 2278-2285</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2170/1812</dc:relation></oai_dc:dc>