Jurnal
SINTA 1
Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique
Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 2 (2016)
ISSN 2089-3191, 2302-9285
Terbit 2016-06-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
The lightning energy can be very harmfull to the wind turbine farm components.This paper attempts to evaluate the overvoltages at the sensitive points in wind farm, using ATP-EMTP package program.Four cases were performed; a) the transient voltage distribution in the insulating layer of the control line, b) the transient voltage on the control equipment, c) the coupling voltage between the tower and the control, and, d) the transient voltage distribution in the wind turbine WT generator, boast transformers and grid.These cases were performed under different lightning current conditions and at conventional design and proper design of grounding system.The results show that the ground potential rise (GPR) is reduced with using the proper design of wind turbine ground system, but the induced voltage at the control system will not affected.This work determines the optimum location of wind turbine at the areas of maximum lightning incidence.Ant colony optimization (ACO) technique is implemented to find the optimum wind farm location.This work enhances the protection strategy of the wind farms against lightning stroke.
Jaringan kolaborasi para penulis
7 penulis ·
10 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Benha University Egyptian Russian University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique</dc:title><dc:creator>Mousa A. Abd‐Allah</dc:creator><dc:creator>A. Said</dc:creator><dc:creator>Mahmoud Nour Ali</dc:creator><dc:subject>lightning protection</dc:subject><dc:subject>wind farms</dc:subject><dc:subject>wind turbines</dc:subject><dc:subject>lightning overvoltage</dc:subject><dc:subject>ground potential rise</dc:subject><dc:subject>grounding systems</dc:subject><dc:subject>ant colony optimization</dc:subject><dc:subject>lightning incidence</dc:subject><dc:subject>induced voltage</dc:subject><dc:description xml:lang="en">The lightning energy can be very harmfull to the wind turbine farm components.This paper attempts to evaluate the overvoltages at the sensitive points in wind farm, using ATP-EMTP package program.Four cases were performed; a) the transient voltage distribution in the insulating layer of the control line, b) the transient voltage on the control equipment, c) the coupling voltage between the tower and the control, and, d) the transient voltage distribution in the wind turbine WT generator, boast transformers and grid.These cases were performed under different lightning current conditions and at conventional design and proper design of grounding system.The results show that the ground potential rise (GPR) is reduced with using the proper design of wind turbine ground system, but the induced voltage at the control system will not affected.This work determines the optimum location of wind turbine at the areas of maximum lightning incidence.Ant colony optimization (ACO) technique is implemented to find the optimum wind farm location.This work enhances the protection strategy of the wind farms against lightning stroke.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.11591/eei.v5i2.618</dc:identifier><dc:identifier>10.11591/eei.v5i2.618</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 2 (2016)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
3 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Abd‐Allah, M. A., Said, A., & Ali, M. N. (2016). Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique. Bulletin of Electrical Engineering and Informatics, 5(2). https://doi.org/10.11591/eei.v5i2.618
Salin
IEEE
M. A. Abd‐Allah, A. Said, and M. N. Ali, “Mitigation of Lightning Hazards at the More Sensitive Points in Wind Farms Using Ant-Colony Optimization Technique,” Bulletin of Electrical Engineering and Informatics, vol. 5, no. 2, 2016, doi: 10.11591/eei.v5i2.618.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.