Performance comparison of automatic peak detection for signal analyser

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 1 (2019) · hlm. 105–113

DOI
10.11591/eei.v8i1.1394
ISSN
2089-3191, 2302-9285
Terbit
2019-03-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The aim of this paper is to propose a new peak detection method for a portable device, which know as modified automatic threshold peak detection (M-ATPD). M-ATPD evolves out of ATPD with a focus on reducing computational time. The proposed method replaces the clustering threshold calculation in ATPD with a standard deviation threshold calculation. M-ATPD reduces computational time by 2 times faster compared to ATPD for control signal and 8.65 times faster compared to ATPD for raw biosignals. Modified ATPD also shows a slight improvement in terms of detection error, with a decrease of about 6.66% to 13.33% in peak detection of noise signals. Modified ATPD successfully fixes the error of peak detection on pulse control signals associated with ATPD. For raw biosignals, in total M-ATPD achieved 19.41% lower detection error compare to ATPD.

Kata kunci

Jaringan kolaborasi para penulis

33 penulis · 126 tautan kepenulisan bersama · 90 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Universiti Malaysia Perlis
  • University of Indonesia
  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • Universiti of Malaysia Sabah
  • National Taiwan University of Science and Technology
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yuri PamungkasInstitut Teknologi Sepuluh Nopember3
M. N. A. UdaUniversiti of Malaysia Sabah3
Wawan YunantoNational Taiwan University of Science and Technology2
Abdul KarimHallym University1
Yamin ThweRajamangala University of Technology1
Tegar Anugrah FirdausInstitut Teknologi Sepuluh Nopember1
Bryan RaisInstitut Teknologi Sepuluh Nopember1
Marcelinus Jonathan SalimInstitut Teknologi Sepuluh Nopember1
Andhika Rastra NegaraInstitut Teknologi Sepuluh Nopember1
Muhammad Qaiser Zaydan ZiaInstitut Teknologi Sepuluh Nopember1
Muhammad Imam SuryaIndonesian Institute of Sciences1
Siti Fauziyah RahmanUniversity of Indonesia1
Irfan MartiansyahIndonesian Institute of Sciences1
Wiguna RahmanNational Research and Innovation Agency1
Yudan WhulanzaUniversity of Indonesia1
Adella JosephinUniversity of Indonesia1
Kenny LischerUniversity of Indonesia1
Irzaman IrzamanIPB University1
Z. JamalAfiliasi tidak diketahui1
Agus SubagioDiponegoro University1
Pepen ArifinBandung Institute of Technology1
Fitri Suryani ArsyadSriwijaya University1
Budi MulyantiIndonesia University of Education1
M. BarmawiBandung Institute of Technology1
Evi TriandiniInstitut Teknologi Dan Bisnis STIKOM Bali1
Yuri PamungkasInstitut Teknologi Sepuluh Nopember1
Rahmah Yasinta RangkutiInstitut Teknologi Sepuluh Nopember1
Kanittha NakkliangValaya Alongkorn Rajabhat University1
Chan Boon ChengUniversiti Malaysia Perlis1
Achmad SyaifudinInstitut Teknologi Sepuluh Nopember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Performance comparison of automatic peak detection for signal analyser</dc:title><dc:creator>Teh Yi Jun</dc:creator><dc:creator>Asral Bahari Jambek</dc:creator><dc:creator>U. Hashim</dc:creator><dc:subject>peak detection</dc:subject><dc:subject>portable devices</dc:subject><dc:subject>computation time reduction</dc:subject><dc:subject>standard deviation threshold</dc:subject><dc:subject>clustering threshold</dc:subject><dc:subject>physiological signals</dc:subject><dc:subject>control signals</dc:subject><dc:subject>detection error</dc:subject><dc:description xml:lang="en">The aim of this paper is to propose a new peak detection method for a portable device, which know as modified automatic threshold peak detection (M-ATPD). M-ATPD evolves out of ATPD with a focus on reducing computational time. The proposed method replaces the clustering threshold calculation in ATPD with a standard deviation threshold calculation. M-ATPD reduces computational time by 2 times faster compared to ATPD for control signal and 8.65 times faster compared to ATPD for raw biosignals. Modified ATPD also shows a slight improvement in terms of detection error, with a decrease of about 6.66% to 13.33% in peak detection of noise signals. Modified ATPD successfully fixes the error of peak detection on pulse control signals associated with ATPD. For raw biosignals, in total M-ATPD achieved 19.41% lower detection error compare to ATPD.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i1.1394</dc:identifier><dc:identifier>10.11591/eei.v8i1.1394</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 1 (2019); 105-113</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/1394/1114</dc:relation></oai_dc:dc>