Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Camera-projector calibration for near infrared imaging system

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 1 (2020) · hlm. 160–170

DOI
10.11591/eei.v9i1.1697
ISSN
2089-3191, 2302-9285
Terbit
2020-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Advanced biomedical engineering technologies are continuously changing the medical practices to improve medical care for patients. Needle insertion navigation during intravenous catheterization process via Near infrared (NIR) and camera-projector is one solution. However, the central point of the problem is the image captured by camera misaligns with the image projected back on the object of interest. This causes the projected image not to be overlaid perfectly in the real-world. In this paper, a camera-projector calibration method is presented. Polynomial algorithm was used to remove the barrel distortion in captured images. Scaling and translation transformations are used to correct the geometric distortions introduced in the image acquisition process. Discrepancies in the captured and projected images are assessed. The accuracy of the image and the projected image is 90.643%. This indicates the feasibility of the captured approach to eliminate discrepancies in the projection and navigation images.

Kata kunci

Jaringan kolaborasi para penulis

18 penulis · 55 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • University of Pembangunan Nasional Veteran Jawa Timur
  • Universiti Sains Malaysia
  • Universitas Dinamika
  • Institut Penyelidikan Keselamatan Jalan Raya Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Zulhaidi Mohd JawiInstitut Penyelidikan Keselamatan Jalan Raya Malaysia1
Mohamad Heerwan Bin PeeieUniversiti Malaysia Pahang Al-Sultan Abdullah1
Ericsson YongUniversiti Malaysia Pahang Al-Sultan Abdullah1
Abdullah ZulkifliUniversiti Malaysia Pahang Al-Sultan Abdullah1
Muhammad Izhar IshakUniversiti Malaysia Pahang Al-Sultan Abdullah1
Muhammad Aizzat ZakariaUniversiti Malaysia Pahang Al-Sultan Abdullah1
Intan Suhana Mohd RazelanUniversiti Malaysia Pahang Al-Sultan Abdullah1
Ahmad Fakhri Ab. NasirUniversiti Malaysia Pahang Al-Sultan Abdullah1
Eva Yulia PuspaningrumUniversity of Pembangunan Nasional Veteran Jawa Timur1
I Gede Susrama Mas DiyasaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Vaizal Asy’ariUniversity of Pembangunan Nasional Veteran Jawa Timur1
Victor Immanuel SunarkoUniversity of Pembangunan Nasional Veteran Jawa Timur1
Jusak JusakUniversitas Dinamika1
Heri PratiknoUniversitas Dinamika1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Camera-projector calibration for near infrared imaging system</dc:title><dc:creator>Marlina Yakno</dc:creator><dc:creator>Junita Mohamad–Saleh</dc:creator><dc:creator>Mohd Zamri Ibrahim</dc:creator><dc:creator>Wan Nur Azhani W. Samsudin</dc:creator><dc:subject>camera-projector calibration</dc:subject><dc:subject>near-infrared imaging</dc:subject><dc:subject>intravenous catheterization</dc:subject><dc:subject>barrel distortion correction</dc:subject><dc:subject>geometric distortion correction</dc:subject><dc:subject>image registration</dc:subject><dc:description xml:lang="en">Advanced biomedical engineering technologies are continuously changing the medical practices to improve medical care for patients. Needle insertion navigation during intravenous catheterization process via Near infrared (NIR) and camera-projector is one solution. However, the central point of the problem is the image captured by camera misaligns with the image projected back on the object of interest. This causes the projected image not to be overlaid perfectly in the real-world. In this paper, a camera-projector calibration method is presented. Polynomial algorithm was used to remove the barrel distortion in captured images. Scaling and translation transformations are used to correct the geometric distortions introduced in the image acquisition process. Discrepancies in the captured and projected images are assessed. The accuracy of the image and the projected image is 90.643%. This indicates the feasibility of the captured approach to eliminate discrepancies in the projection and navigation images.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i1.1697</dc:identifier><dc:identifier>10.11591/eei.v9i1.1697</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 160-170</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1697/1268</dc:relation></oai_dc:dc>