Abstrak
Heart rate (HR) is one of important indicator for human physiological diagnosis, and camera can be used to detect it via photoplethysmograph (PPG) signal extraction. In doing so, number of sample images required to measure the HR signal, and quality of the images itself are important to yield an accurate reading. This paper tackles such an issue by analyzing the effect of sampling interval to HR reading in compressed and original video format, obtained in various ranging locations. Technically, important facial points from video stream were estimated by using cascade regression facial tracker. Based on the facial points, region of interest (ROI) was constructed where non-rigid movement is minimal. Next, PPG signal was extracted by calculating the average value of green pixel intensity from the ROI. Following that, illumination variation was separated from the signal via independent component analysis (ICA). The PPG signal was further processed using series of signal filtering techniques to exclude frequencies beyond range of interest prior estimate the HR. From the experiment it can be observed that sampling time of 2 seconds in uncompressed video shows promising HR within the range of 1 to 5 meters.
Jaringan kolaborasi para penulis
15 penulis ·
52 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Tun Hussein Onn University of Malaysia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system</dc:title><dc:creator>Norwahidah Ibrahim</dc:creator><dc:creator>Razali Tomari</dc:creator><dc:creator>Wan Nurshazwani Wan Zakaria</dc:creator><dc:subject>non-contact heart rate monitoring</dc:subject><dc:subject>photoplethysmography</dc:subject><dc:subject>video compression</dc:subject><dc:subject>facial video</dc:subject><dc:subject>sampling interval</dc:subject><dc:subject>facial landmark tracking</dc:subject><dc:subject>region of interest</dc:subject><dc:subject>independent component analysis</dc:subject><dc:subject>illumination variation</dc:subject><dc:subject>signal filtering</dc:subject><dc:subject>camera distance</dc:subject><dc:description xml:lang="en">Heart rate (HR) is one of important indicator for human physiological diagnosis, and camera can be used to detect it via photoplethysmograph (PPG) signal extraction. In doing so, number of sample images required to measure the HR signal, and quality of the images itself are important to yield an accurate reading. This paper tackles such an issue by analyzing the effect of sampling interval to HR reading in compressed and original video format, obtained in various ranging locations. Technically, important facial points from video stream were estimated by using cascade regression facial tracker. Based on the facial points, region of interest (ROI) was constructed where non-rigid movement is minimal. Next, PPG signal was extracted by calculating the average value of green pixel intensity from the ROI. Following that, illumination variation was separated from the signal via independent component analysis (ICA). The PPG signal was further processed using series of signal filtering techniques to exclude frequencies beyond range of interest prior estimate the HR. From the experiment it can be observed that sampling time of 2 seconds in uncompressed video shows promising HR within the range of 1 to 5 meters.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i1.1855</dc:identifier><dc:identifier>10.11591/eei.v9i1.1855</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 403-410</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1855/1296</dc:relation></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Belum diperiksa
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ibrahim, N., Tomari, R., & Zakaria, W. N. W. (2020). Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system. Bulletin of Electrical Engineering and Informatics, 9(1), 403–410. https://doi.org/10.11591/eei.v9i1.1855
Salin
IEEE
N. Ibrahim, R. Tomari, and W. N. W. Zakaria, “Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system,” Bulletin of Electrical Engineering and Informatics, vol. 9, no. 1, pp. 403–410, 2020, doi: 10.11591/eei.v9i1.1855.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.