Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 1 (2020) · hlm. 403–410

DOI
10.11591/eei.v9i1.1855
ISSN
2089-3191, 2302-9285
Terbit
2020-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Heart rate (HR) is one of important indicator for human physiological diagnosis, and camera can be used to detect it via photoplethysmograph (PPG) signal extraction. In doing so, number of sample images required to measure the HR signal, and quality of the images itself are important to yield an accurate reading. This paper tackles such an issue by analyzing the effect of sampling interval to HR reading in compressed and original video format, obtained in various ranging locations. Technically, important facial points from video stream were estimated by using cascade regression facial tracker. Based on the facial points, region of interest (ROI) was constructed where non-rigid movement is minimal. Next, PPG signal was extracted by calculating the average value of green pixel intensity from the ROI. Following that, illumination variation was separated from the signal via independent component analysis (ICA). The PPG signal was further processed using series of signal filtering techniques to exclude frequencies beyond range of interest prior estimate the HR. From the experiment it can be observed that sampling time of 2 seconds in uncompressed video shows promising HR within the range of 1 to 5 meters.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 52 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nurmiza Binti OthmanTun Hussein Onn University of Malaysia7
Syadia Nabilah Mohd SafuanTun Hussein Onn University of Malaysia4
Mohd Norzali Haji MohdTun Hussein Onn University of Malaysia4
Nor Surayahani SurianiTun Hussein Onn University of Malaysia4
Cham Ying KitTun Hussein Onn University of Malaysia2
Jacqueline Ang Jie YiTun Hussein Onn University of Malaysia2
Nicholas Tan Chun ShengTun Hussein Onn University of Malaysia2
Muhammad Fuad bin KassimTun Hussein Onn University of Malaysia2
Suhaila SariTun Hussein Onn University of Malaysia2
Md Nor Ramdon BaharomTun Hussein Onn University of Malaysia2
Muhamad Fikri Shahkhirin BirahimTun Hussein Onn University of Malaysia2
Luqman Nol HakimTun Hussein Onn University of Malaysia2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system</dc:title><dc:creator>Norwahidah Ibrahim</dc:creator><dc:creator>Razali Tomari</dc:creator><dc:creator>Wan Nurshazwani Wan Zakaria</dc:creator><dc:subject>non-contact heart rate monitoring</dc:subject><dc:subject>photoplethysmography</dc:subject><dc:subject>video compression</dc:subject><dc:subject>facial video</dc:subject><dc:subject>sampling interval</dc:subject><dc:subject>facial landmark tracking</dc:subject><dc:subject>region of interest</dc:subject><dc:subject>independent component analysis</dc:subject><dc:subject>illumination variation</dc:subject><dc:subject>signal filtering</dc:subject><dc:subject>camera distance</dc:subject><dc:description xml:lang="en">Heart rate (HR) is one of important indicator for human physiological diagnosis, and camera can be used to detect it via photoplethysmograph (PPG) signal extraction. In doing so, number of sample images required to measure the HR signal, and quality of the images itself are important to yield an accurate reading. This paper tackles such an issue by analyzing the effect of sampling interval to HR reading in compressed and original video format, obtained in various ranging locations. Technically, important facial points from video stream were estimated by using cascade regression facial tracker. Based on the facial points, region of interest (ROI) was constructed where non-rigid movement is minimal. Next, PPG signal was extracted by calculating the average value of green pixel intensity from the ROI. Following that, illumination variation was separated from the signal via independent component analysis (ICA). The PPG signal was further processed using series of signal filtering techniques to exclude frequencies beyond range of interest prior estimate the HR. From the experiment it can be observed that sampling time of 2 seconds in uncompressed video shows promising HR within the range of 1 to 5 meters.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i1.1855</dc:identifier><dc:identifier>10.11591/eei.v9i1.1855</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 403-410</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1855/1296</dc:relation></oai_dc:dc>