Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Flexible ECG circuit fabrication and application using vinyl cutting technique

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 6 (2020) · hlm. 2319–2325

DOI
10.11591/eei.v9i6.2197
ISSN
2089-3191, 2302-9285
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The aim of this study is to prove the capability of vinyl cutting technique to cut the conductive traces of electronic circuit layout which used a copper tape (Copper tape 1181 from 3M) on flexible substrate to replace the method of using nano-scale particle material. A wireless electrocardiography (ECG) circuit was integrated and fabricated on flexible substrate, namely a polyethylene terephthalate (PET) substrate by using vinyl cutting method to produce the conductive line traces. After that, the fabricated circuit is used for acquiring ECG signals from a patient simulator and human subjects to measure the performance differences and compatibility as a wearable device. In the data processing stage, ECG data were denoised using sym20 from Wavelet Transform tool provided by MATLAB. Then, Signal-to-noise-ratio (SNR) was calculated and used as the signal quality indicator. At the end of the study, flexible circuit performance was compared to MIT-BIH Arrhythmia database and it shows that there is no significance difference between both. In conclusion, vinyl cutting method shows a promising fabrication output on PET substrate as the performance of both flexible ECG circuit is comparable with rigid ECG circuit by a previous study.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 39 tautan kepenulisan bersama · 25 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Universiti Malaysia Terengganu
  • TATI University College
  • Ho Chi Minh City University of Technology
  • University of Malaya
  • Swiss German University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hanis Camelia MuharUniversity of Technology Malaysia3
Syaidah Md SalehUniversity of Technology Malaysia2
Dedy H. B. WicaksonoSwiss German University2
Ameer Farhan Mohd ArzamanUniversiti Malaysia Terengganu1
Hayatul Safrah SallehUniversiti Malaysia Terengganu1
Abdul Mutalib EmbongUniversiti Malaysia Terengganu1
Kais Amir KadhimUniversiti Malaysia Terengganu1
Norzamziah AfzainizamTATI University College1
Loi Hoang Huy Phuoc PhamHo Chi Minh City University of Technology1
Nur Yuhanis Mohd NasirUniversity of Malaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Flexible ECG circuit fabrication and application using vinyl cutting technique</dc:title><dc:creator>Noor Syazwana Sahar</dc:creator><dc:creator>Nurul Ashikin Abdul-Kadir</dc:creator><dc:creator>Fauzan Khairi Che Harun</dc:creator><dc:subject>copper tape</dc:subject><dc:subject>polyethylene terephthalate substrate</dc:subject><dc:subject>wearable ECG</dc:subject><dc:subject>ECG denoising</dc:subject><dc:subject>wavelet transform</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:subject>MIT-BIH arrhythmia database</dc:subject><dc:description xml:lang="en">The aim of this study is to prove the capability of vinyl cutting technique to cut the conductive traces of electronic circuit layout which used a copper tape (Copper tape 1181 from 3M) on flexible substrate to replace the method of using nano-scale particle material. A wireless electrocardiography (ECG) circuit was integrated and fabricated on flexible substrate, namely a polyethylene terephthalate (PET) substrate by using vinyl cutting method to produce the conductive line traces. After that, the fabricated circuit is used for acquiring ECG signals from a patient simulator and human subjects to measure the performance differences and compatibility as a wearable device. In the data processing stage, ECG data were denoised using sym20 from Wavelet Transform tool provided by MATLAB. Then, Signal-to-noise-ratio (SNR) was calculated and used as the signal quality indicator. At the end of the study, flexible circuit performance was compared to MIT-BIH Arrhythmia database and it shows that there is no significance difference between both. In conclusion, vinyl cutting method shows a promising fabrication output on PET substrate as the performance of both flexible ECG circuit is comparable with rigid ECG circuit by a previous study.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i6.2197</dc:identifier><dc:identifier>10.11591/eei.v9i6.2197</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 6 (2020); 2319-2325</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2197/1815</dc:relation></oai_dc:dc>