Melola Discovery

← Melola Discovery

Jurnal SINTA 1

An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 1 (2021) · hlm. 508–515

DOI
10.11591/eei.v10i1.2694
ISSN
2089-3191, 2302-9285
Terbit
2021-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

In diagnosing coronary artery disease, measurement of the cross-sectional area of the lumen, maximum and minimum diameter is very important. Mainly, it will be used to confirm the diagnosing, to predict the stenosis if any and to ensure the size of the stent to be used. However, the measurement only offers by the existing software and some of the software needs human interaction to complete the process. The purpose of this paper is to present the algorithm to measure the region of interest (ROI) on intravascular ultrasound (IVUS) using an image processing technique. The methodology starts with image acquisition process followed by image segmentation. After that, border detection for each ROI was detected and the algorithm was applied to calculate the corresponding region. The result shows that the measurement is accurate and could be used not only for IVUS but applicable to solid circle and unsymmetrical circle shape.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 29 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Putra Malaysia
  • Universiti Teknologi MARA
  • Northern Technical University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Murizah Binti KassimUniversiti Teknologi MARA1
Muhammad Azim NazriUniversiti Teknologi MARA1
Che Nur Shafareen AferaUniversiti Putra Malaysia1
Norakmar Arbain SulaimanUniversiti Teknologi MARA1
Teh Noranis Mohd ArisUniversiti Putra Malaysia1
Maher Talal AlasaadyNorthern Technical University1
Nurfadhlina Mohd SharefUniversiti Putra Malaysia1
Noridayu Binti ManshorUniversiti Putra Malaysia1
Ban Safir KhalafUniversiti Putra Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques</dc:title><dc:creator>Suhaili Beeran Kutty</dc:creator><dc:creator>Rahmita Wirza O. K. Rahmat</dc:creator><dc:creator>Sazzli Shahlan Kassim</dc:creator><dc:creator>Hizmawati Madzin</dc:creator><dc:creator>Hazlina Hamdan</dc:creator><dc:subject>intravascular ultrasound</dc:subject><dc:subject>coronary artery disease</dc:subject><dc:subject>lumen cross-sectional area</dc:subject><dc:subject>vessel diameter measurement</dc:subject><dc:subject>region of interest measurement</dc:subject><dc:subject>image segmentation</dc:subject><dc:subject>border detection</dc:subject><dc:subject>automated image analysis</dc:subject><dc:description xml:lang="en">In diagnosing coronary artery disease, measurement of the cross-sectional area of the lumen, maximum and minimum diameter is very important. Mainly, it will be used to confirm the diagnosing, to predict the stenosis if any and to ensure the size of the stent to be used. However, the measurement only offers by the existing software and some of the software needs human interaction to complete the process. The purpose of this paper is to present the algorithm to measure the region of interest (ROI) on intravascular ultrasound (IVUS) using an image processing technique. The methodology starts with image acquisition process followed by image segmentation. After that, border detection for each ROI was detected and the algorithm was applied to calculate the corresponding region. The result shows that the measurement is accurate and could be used not only for IVUS but applicable to solid circle and unsymmetrical circle shape.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i1.2694</dc:identifier><dc:identifier>10.11591/eei.v10i1.2694</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 1 (2021); 508-515</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2694/1914</dc:relation></oai_dc:dc>