Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Widespread compact fluorescent lamp evaluations in 50 Hz electrical network

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 3 (2023) · hlm. 1267–1275

DOI
10.11591/eei.v12i3.4904
ISSN
2089-3191, 2302-9285
Terbit
2023-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Rapid development in electrical technology has imposed strong challenges to modern power system. Power quality has become a great concern due to proliferation of power electronic technology in modern electrical loads. Specifically for lighting load such as compact fluorescent lamps (CFLs), one of the concerning issues is harmonics. CFL is a cost-competitive and energy efficient compared to incandescent lamp. Inevitably, CFL produces harmonics current due to nonlinearity behaviour of the electronic ballast circuit. This paper presents a study on the widespread installation of CFL lamps in electrical power network. Initially, the harmonic current characteristics of local-branded CFL was identified from laboratory measurement. Then, a simulated CFL model was developed in MATLAB/Simulink to replicate the identified characteristics. The same step was repeated for other two different brands where eventually all models were embedded into a distribution network. The results show that at low voltage level, with installation more than 50 units for each type of CFL, the harmonic voltage distortion exceeded the 8% total harmonic distortion (THD) limit as stipulated in EN50160 standard. However, at higher voltage, the amount of THD decreased to average 0.94% and further down to average 0.28% at small transmission voltage level.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 72 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • International Islamic University Malaysia
  • Universiti Teknikal Malaysia Melaka
  • Tun Hussein Onn University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nur Nabihah Rusyda RoslanUniversiti Malaysia Pahang Al-Sultan Abdullah3
NoorFatin Farhanie Mohd FauziUniversiti Malaysia Pahang Al-Sultan Abdullah3
Fauziyah SalehuddinUniversiti Teknikal Malaysia Melaka1
Ahmad Nizamuddin Muhammad MustafaUniversiti Teknikal Malaysia Melaka1
Yaumee Natasha JusohUniversiti Teknikal Malaysia Melaka1
Omsri Vinasha AliyaselvamUniversiti Teknikal Malaysia Melaka1
N. ZainalUniversiti Teknikal Malaysia Melaka1
Faiz ArithUniversiti Teknikal Malaysia Melaka1
Abu Zaharin AhmadUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohammad Fadhil AbasUniversiti Malaysia Pahang Al-Sultan Abdullah1
Muhamad Zahim SujodUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohd Shafie BakarUniversiti Malaysia Pahang Al-Sultan Abdullah1
N. Md. SaadUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohd Shawal JadinUniversiti Malaysia Pahang Al-Sultan Abdullah1
Azzmer Azzar Abdul HamidInternational Islamic University Malaysia1
Khairiah RazaliInternational Islamic University Malaysia1
Noor Hasniza Md ZinInternational Islamic University Malaysia1
Hanani Ahmad YusofInternational Islamic University Malaysia1
Kamarul Rahim KamarudinTun Hussein Onn University of Malaysia1
Aisyah Mohamed RehanInternational Islamic University Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Widespread compact fluorescent lamp evaluations in 50 Hz electrical network</dc:title><dc:creator>Ruhaizad Ishak</dc:creator><dc:creator>Ahmad Syahiman Mohd Shah</dc:creator><dc:creator>Mohd Ikhwan Muhammad Ridzuan</dc:creator><dc:creator>Noraslinda Muhamad Bunnori</dc:creator><dc:subject>compact fluorescent lamps</dc:subject><dc:subject>current harmonics</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>power quality</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>electronic ballast</dc:subject><dc:subject>lighting loads</dc:subject><dc:subject>EN 50160</dc:subject><dc:subject>power electronic loads</dc:subject><dc:description xml:lang="en">Rapid development in electrical technology has imposed strong challenges to modern power system. Power quality has become a great concern due to proliferation of power electronic technology in modern electrical loads. Specifically for lighting load such as compact fluorescent lamps (CFLs), one of the concerning issues is harmonics. CFL is a cost-competitive and energy efficient compared to incandescent lamp. Inevitably, CFL produces harmonics current due to nonlinearity behaviour of the electronic ballast circuit. This paper presents a study on the widespread installation of CFL lamps in electrical power network. Initially, the harmonic current characteristics of local-branded CFL was identified from laboratory measurement. Then, a simulated CFL model was developed in MATLAB/Simulink to replicate the identified characteristics. The same step was repeated for other two different brands where eventually all models were embedded into a distribution network. The results show that at low voltage level, with installation more than 50 units for each type of CFL, the harmonic voltage distortion exceeded the 8% total harmonic distortion (THD) limit as stipulated in EN50160 standard. However, at higher voltage, the amount of THD decreased to average 0.94% and further down to average 0.28% at small transmission voltage level.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i3.4904</dc:identifier><dc:identifier>10.11591/eei.v12i3.4904</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 3 (2023); 1267-1275</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4904/3193</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>