Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Reliability improvement of multi-phase interleaved DC-DC converters for fuel cell electric vehicle applications

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 5 (2023) · hlm. 2553–2560

DOI
10.11591/eei.v12i5.4674
ISSN
2089-3191, 2302-9285
Terbit
2023-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper suggests a fast and low-cost method that can be applied in several DC/DC converter topologies for detecting open circuit faults (OCFs) and short circuit faults (SCFs). The suggested method may identify the faults of several power switches even if they occur simultaneously in multi-phase interleaved boost converters (MPh-IBC) by using just the sensors needed to control the converter. This fault detection method (FDM) is based mainly on comparing the measured inductor current and two fault detection thresholds, one for OCFs detection and the other for SCFs detection. This method combined with a corrective strategy to mitigate the negative impacts of OCFs, particularly the significant rise in the ripple of the DC bus voltage and the fuel cell (FC) current, which reduces FC aging and converter reliability. The simulation findings indicate the FDM's excellent performance and speed, as well as its usefulness in detecting defects of many power switches in the converter, with a fault detection time of up to 1.7 µs. The acquired findings further show the excellent effectiveness of the corrective strategy in reducing these ripples in the event of one or two faults.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 8 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Biskra
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. BachaUniversity of Biskra2
Ramzi SaadiUniversity of Biskra2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Reliability improvement of multi-phase interleaved DC-DC converters for fuel cell electric vehicle applications</dc:title><dc:creator>Hicham Mehida</dc:creator><dc:creator>A. Aboubou</dc:creator><dc:creator>Mohamed Yacine Ayad</dc:creator><dc:subject>fault detection</dc:subject><dc:subject>DC-DC converter</dc:subject><dc:subject>open-circuit fault</dc:subject><dc:subject>short-circuit faults</dc:subject><dc:subject>fuel cell vehicles</dc:subject><dc:subject>inductor current</dc:subject><dc:subject>DC bus voltage ripple</dc:subject><dc:subject>fault mitigation</dc:subject><dc:subject>converter reliability</dc:subject><dc:subject>power switching devices</dc:subject><dc:description xml:lang="en">This paper suggests a fast and low-cost method that can be applied in several DC/DC converter topologies for detecting open circuit faults (OCFs) and short circuit faults (SCFs). The suggested method may identify the faults of several power switches even if they occur simultaneously in multi-phase interleaved boost converters (MPh-IBC) by using just the sensors needed to control the converter. This fault detection method (FDM) is based mainly on comparing the measured inductor current and two fault detection thresholds, one for OCFs detection and the other for SCFs detection. This method combined with a corrective strategy to mitigate the negative impacts of OCFs, particularly the significant rise in the ripple of the DC bus voltage and the fuel cell (FC) current, which reduces FC aging and converter reliability. The simulation findings indicate the FDM's excellent performance and speed, as well as its usefulness in detecting defects of many power switches in the converter, with a fault detection time of up to 1.7 µs. The acquired findings further show the excellent effectiveness of the corrective strategy in reducing these ripples in the event of one or two faults.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i5.4674</dc:identifier><dc:identifier>10.11591/eei.v12i5.4674</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2553-2560</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4674/3363</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>