Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Maximum allowable hp rating of 3-phase induction motor fed through a stand-alone constant V/f controlled DFIG via RSC

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · hlm. 832–844

DOI
10.11591/eei.v13i2.6088
ISSN
2089-3191, 2302-9285
Terbit
2024-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper presents a scheme to start three-phase induction motors (IMs) directly connected to terminals of constant V/f controlled doubly fed induction generator (DFIG) through the rotor side converter (RSC). The proposed control is achieved by controlling the output voltage and frequency of stand-alone DFIG via controlling an injected voltage into the rotor circuit through the RSC. The control scheme provides a search for maximum rating of the three-phase IM which can be supplied from a DFIG. The search technique is based on using a simplified mathematical model to find the capability limits of the RSC and DFIG. It is found that these parameters depend on the stator frequency and rotor slip. Therefore, an investigation is performed to find the lowest frequency and the corresponding allowable maximum rating for the IM to be safely started. A typical example is provided in the paper for a 15 kW DFIG. It is shown that this generator could supply a three-phase IM with a maximum rating of 1-hp if it operated at nominal outputs, voltage and frequency, during start-up period. While, using the proposed technique, the same generator could start-up a three-phase IM with maximum power rating of 7.25 hp.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 112 tautan kepenulisan bersama · 67 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Benha University
  • Universitas Ahmad Dahlan
  • Diponegoro University
  • Universiti Malaysia Perlis
  • Cairo University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Auzani JidinUniversiti Teknikal Malaysia Melaka40
Nik Rumzi Nik IdrisUniversity of Technology Malaysia31
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka28
Awang JusohUniversity of Technology Malaysia21
Mustafa ManapUniversiti Teknikal Malaysia Melaka17
Mohammad JannatiUniversity of Technology Malaysia16
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia16
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka13
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka13
Shahreen binti KasimTun Hussein Onn University of Malaysia11
Mohamed SalemUniversiti Sains Malaysia11
Ibrahim AlhamrouniUniversity of Kuala Lumpur10
Lina HandayaniUniversitas Ahmad Dahlan9
Mahmoud ZadehbagheriIslamic Azad University Yasuj9
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka7
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka7
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka7
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka7
Shahrin Md AyobUniversity of Technology Malaysia7
Hendril Satrian PurnamaAfiliasi tidak diketahui6
Watra ArsadiandoAfiliasi tidak diketahui6
Mochammad FactaDiponegoro University6
Mohammad Faridun Naim TajuddinUniversiti Malaysia Perlis6
Munawar Agus RiyadiDiponegoro University5
Deris StiawanSriwijaya University5
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka5
Ahmed Hussein AliIraqi University5
Tri WahonoUniversitas Ahmad Dahlan5
Azralmukmin AzmiUniversiti Malaysia Perlis5
Norjulia Mohamad NordinUniversity of Technology Malaysia5
Mostafa Abdulghafoor MohammedAl-Imam Al-Adham University College5
Imam Much Ibnu SubrotoSultan Agung Islamic University4
Muhammad AdoUniversity of Technology Malaysia4
Mehdi DadkhahIslamic Azad University, Tehran4

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Maximum allowable hp rating of 3-phase induction motor fed through a stand-alone constant V/f controlled DFIG via RSC</dc:title><dc:creator>Mohamed Sharawy</dc:creator><dc:creator>Adel Shaltout</dc:creator><dc:creator>Omar El-Sayed Mohammed Youssef</dc:creator><dc:creator>Mahmoud A. Al-Ahmar</dc:creator><dc:creator>Naser Abdel‐Rahim</dc:creator><dc:creator>Tole Sutikno</dc:creator><dc:subject>doubly fed induction generator</dc:subject><dc:subject>three-phase induction motor</dc:subject><dc:subject>V/f control</dc:subject><dc:subject>rotor side converter</dc:subject><dc:subject>stand-alone generator</dc:subject><dc:subject>motor starting</dc:subject><dc:description xml:lang="en">This paper presents a scheme to start three-phase induction motors (IMs) directly connected to terminals of constant V/f controlled doubly fed induction generator (DFIG) through the rotor side converter (RSC). The proposed control is achieved by controlling the output voltage and frequency of stand-alone DFIG via controlling an injected voltage into the rotor circuit through the RSC. The control scheme provides a search for maximum rating of the three-phase IM which can be supplied from a DFIG. The search technique is based on using a simplified mathematical model to find the capability limits of the RSC and DFIG. It is found that these parameters depend on the stator frequency and rotor slip. Therefore, an investigation is performed to find the lowest frequency and the corresponding allowable maximum rating for the IM to be safely started. A typical example is provided in the paper for a 15 kW DFIG. It is shown that this generator could supply a three-phase IM with a maximum rating of 1-hp if it operated at nominal outputs, voltage and frequency, during start-up period. While, using the proposed technique, the same generator could start-up a three-phase IM with maximum power rating of 7.25 hp.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i2.6088</dc:identifier><dc:identifier>10.11591/eei.v13i2.6088</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 832-844</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6088/3672</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>