Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Comparative Analysis of DITC Based Switched Reluctance Motor Using Asymmetric Converter and Four-Level Converter

Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 1 (2016) · hlm. 109–119

DOI
10.11591/eei.v5i1.555
ISSN
2089-3191, 2302-9285
Terbit
2016-03-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

High torque ripple is the main draw of Switched Reluctance Motor (SRM) compared to other conventional motor. Torque ripples can be minimized by Direct Instantaneous Torque Control (DITC) technique. DITC responds against the torque error instantaneously by using hysteresis torque controller and regulate the torque output of the motor within hysteresis band.This paper compares the performance of Switched Reluctance Motor in terms of torque ripples with DITC strategy for both Asymmetric converter and Four-level converter. Asymmetric converter has three states namely magnetization, freewheeling and demagnetiztion states. With four-level converter, fast magnetization and fast demagnetization are also possible. Thus, the current build up and decay time is reduced which improves the dynamic performance. SRM is simulated using DITC scheme with Asymmetric converter and Four-level converter in MATLAB/SIMULINK to analyze torque ripples and it is observed that DITC with four level converter is better than that with Assymetrical converter.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 3 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Osmania University
  • Institute of Science and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sravanthy GaddameedhiInstitute of Science and Technology1
P. SrinivasAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparative Analysis of DITC Based Switched Reluctance Motor Using Asymmetric Converter and Four-Level Converter</dc:title><dc:creator>P. Srinivas</dc:creator><dc:creator>K. Amulya</dc:creator><dc:subject>switched reluctance motor</dc:subject><dc:subject>direct instantaneous torque control</dc:subject><dc:subject>asymmetric converter</dc:subject><dc:subject>four-level converter</dc:subject><dc:subject>torque ripple reduction</dc:subject><dc:subject>dynamic performance</dc:subject><dc:description xml:lang="en">High torque ripple is the main draw of Switched Reluctance Motor (SRM) compared to other conventional motor. Torque ripples can be minimized by Direct Instantaneous Torque Control (DITC) technique. DITC responds against the torque error instantaneously by using hysteresis torque controller and regulate the torque output of the motor within hysteresis band.This paper compares the performance of Switched Reluctance Motor in terms of torque ripples with DITC strategy for both Asymmetric converter and Four-level converter. Asymmetric converter has three states namely magnetization, freewheeling and demagnetiztion states. With four-level converter, fast magnetization and fast demagnetization are also possible. Thus, the current build up and decay time is reduced which improves the dynamic performance. SRM is simulated using DITC scheme with Asymmetric converter and Four-level converter in MATLAB/SIMULINK to analyze torque ripples and it is observed that DITC with four level converter is better than that with Assymetrical converter.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v5i1.555</dc:identifier><dc:identifier>10.11591/eei.v5i1.555</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 1 (2016); 109-119</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>