Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Respiration Monitoring System of Lung Phantom Using Magnetic Sensor

Bulletin of Electrical Engineering and Informatics · Vol. 7 No. 1 (2018) · hlm. 15–20

DOI
10.11591/eei.v7i1.711
ISSN
2089-3191, 2302-9285
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 55 tautan kepenulisan bersama · 22 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sultan Ageng Tirtayasa University
  • Sunan Kalijaga State Islamic University Yogyakarta
  • Universitas Islam Negeri Fatmawati Sukarno Bengkulu
  • Mulawarman University
  • Advocacia-Geral da União
  • Universitas Islam Negeri Sumatera Utara
  • Universitas 17 Agustus 1945 Samarinda
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Teguh FirmansyahSultan Ageng Tirtayasa University3
Fajar AprianiMulawarman University2
Zezen Zainul AliSunan Kalijaga State Islamic University Yogyakarta2
Helena OctavianneAdvocacia-Geral da União2
Cindera PermataSunan Kalijaga State Islamic University Yogyakarta2
Muadil FaizinAfiliasi tidak diketahui1
Yenni Samri Juliati NasutionUniversitas Islam Negeri Sumatera Utara1
R. Dedy Chairil ZainAfiliasi tidak diketahui1
Suhardiman SuhardimanUniversitas 17 Agustus 1945 Samarinda1
Fadil MuhammadSultan Ageng Tirtayasa University1
Rian FahrizalSultan Ageng Tirtayasa University1
Tegar Priyo UtomoSultan Ageng Tirtayasa University1
Islam Md. MuztahidulShizuoka University1
Romi WiryadinataSultan Ageng Tirtayasa University1
Annisa Sucianti NurlianySultan Ageng Tirtayasa University1
Joddy Arya LaksmonoIndonesian Institute of Sciences1
Agus NurhadiSultan Ageng Tirtayasa University1
Windra Bagus SuwandidanSultan Ageng Tirtayasa University1
Aqbal Hasnain Affan AqbalSultan Ageng Tirtayasa University1
Wahyuni MartiningsihSultan Ageng Tirtayasa University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Respiration Monitoring System of Lung Phantom Using Magnetic Sensor</dc:title><dc:creator>Imamul Muttakin</dc:creator><dc:creator>David Abraham</dc:creator><dc:creator>Rocky Alfanz</dc:creator><dc:creator>Rohmadi Rohmadi</dc:creator><dc:subject>respiratory monitoring</dc:subject><dc:subject>lung phantom</dc:subject><dc:subject>magnetic sensors</dc:subject><dc:subject>remote patient monitoring</dc:subject><dc:subject>vital signs monitoring</dc:subject><dc:subject>non-contact sensing</dc:subject><dc:subject>portable devices</dc:subject><dc:subject>breathing pattern</dc:subject><dc:description xml:lang="en">Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2018-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v7i1.711</dc:identifier><dc:identifier>10.11591/eei.v7i1.711</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 7 No 1 (2018); 15-20</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/711/512</dc:relation></oai_dc:dc>