Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Singular value decomposition filtering in high-frame-rate cardiac vector flow imaging

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 1 (2020) · hlm. 171–179

DOI
10.11591/eei.v9i1.1858
ISSN
2089-3191, 2302-9285
Terbit
2020-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Dysfunction of the left ventricle (LV) weakens the cardiac function and affects the physical activity. Echocardiagraphy has been used to visualize the blood flow dynamics and to evaluate the cardiac function. However, the signal processing to suppress the clutter signals should be employed. In this study, we employed the singular value decomposition (SVD) clutter filtering to obtain the cardiac blood speckle images. We also employed the adaptive thresholding metric to determine the proper cutoff values at each phase during the cardiac cycle. Moreover, we employed a depth-dependent SVD clutter filter for more accurate estimation of the cardiac blood echo signals. The 2D blood flow velocity vectors were estimated by applying the block matching method to obtained blood speckle images. The obtained results show that the proposed filter suppressed the clutter signals from left ventricular wall significantly, and the contrast-to-noise ratio (CNR) was improved from -0.5 dB to 13.8 dB by the proposed SVD clutter filtering.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Toyama
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Singular value decomposition filtering in high-frame-rate cardiac vector flow imaging</dc:title><dc:creator>Michiya Mozumi</dc:creator><dc:creator>Ryo Nagaoka</dc:creator><dc:creator>Hideyuki Hasegawa</dc:creator><dc:subject>singular value decomposition</dc:subject><dc:subject>clutter suppression</dc:subject><dc:subject>speckle imaging</dc:subject><dc:subject>left ventricle</dc:subject><dc:subject>adaptive thresholding</dc:subject><dc:subject>block matching</dc:subject><dc:subject>blood flow velocity estimation</dc:subject><dc:subject>high frame rate ultrasound</dc:subject><dc:subject>contrast-to-noise ratio</dc:subject><dc:description xml:lang="en">Dysfunction of the left ventricle (LV) weakens the cardiac function and affects the physical activity. Echocardiagraphy has been used to visualize the blood flow dynamics and to evaluate the cardiac function. However, the signal processing to suppress the clutter signals should be employed. In this study, we employed the singular value decomposition (SVD) clutter filtering to obtain the cardiac blood speckle images. We also employed the adaptive thresholding metric to determine the proper cutoff values at each phase during the cardiac cycle. Moreover, we employed a depth-dependent SVD clutter filter for more accurate estimation of the cardiac blood echo signals. The 2D blood flow velocity vectors were estimated by applying the block matching method to obtained blood speckle images. The obtained results show that the proposed filter suppressed the clutter signals from left ventricular wall significantly, and the contrast-to-noise ratio (CNR) was improved from -0.5 dB to 13.8 dB by the proposed SVD clutter filtering.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i1.1858</dc:identifier><dc:identifier>10.11591/eei.v9i1.1858</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 171-179</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1858/1265</dc:relation></oai_dc:dc>