Method for automatic compensation of a single-phase earth fault

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 3 (2021) · hlm. 1164–1172

DOI
10.11591/eei.v10i3.3021
ISSN
2089-3191, 2302-9285
Terbit
2021-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The paper demonstrates improving the reliability of power supply and operating safety of power receivers in electric networks of 6-10 kV, by controlling the neutral mode in extended electric networks of 6-10 kV with capacitive earth fault currents above 15 A. The purpose of the study is to increase the reliability of power supply and the safety of operation of power receivers in such electric networks, the establishment of patterns in controlling the neutral mode in extended 6-10 kV electric networks with capacitive earth fault currents above 15 A, as well as the development of a method and device automatic detection of single-phase earth fault current. Grounding methods and neutral modes in electric networks with a voltage of 6-10 kV are considered. The method and device for automatically determining the current of a single-phase earth fault were developed. In the result, the relationship between the active and inductive components of the neutral current during series RL grounding of the network Ia/IL=(0.5÷0.3) was established, which ensures reliable operation of the SPEF protection of both current and directional principles including the changes of capacity abruptly networks caused by switching outgoing lines.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • M. Kh Dulati Taraz State University
  • Taraz State Pedagogical University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Method for automatic compensation of a single-phase earth fault</dc:title><dc:creator>Martebe Zhankuanyshev</dc:creator><dc:creator>Kushkimbayeva Bibara</dc:creator><dc:creator>S. Sh. Egemberdieva</dc:creator><dc:creator>Zhanar S. Esdauletova</dc:creator><dc:creator>Laura Yesmakhanova</dc:creator><dc:subject>single-phase grounding fault</dc:subject><dc:subject>power supply reliability</dc:subject><dc:subject>directional protection</dc:subject><dc:description xml:lang="en">The paper demonstrates improving the reliability of power supply and operating safety of power receivers in electric networks of 6-10 kV, by controlling the neutral mode in extended electric networks of 6-10 kV with capacitive earth fault currents above 15 A. The purpose of the study is to increase the reliability of power supply and the safety of operation of power receivers in such electric networks, the establishment of patterns in controlling the neutral mode in extended 6-10 kV electric networks with capacitive earth fault currents above 15 A, as well as the development of a method and device automatic detection of single-phase earth fault current. Grounding methods and neutral modes in electric networks with a voltage of 6-10 kV are considered. The method and device for automatically determining the current of a single-phase earth fault were developed. In the result, the relationship between the active and inductive components of the neutral current during series RL grounding of the network Ia/IL=(0.5÷0.3) was established, which ensures reliable operation of the SPEF protection of both current and directional principles including the changes of capacity abruptly networks caused by switching outgoing lines.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i3.3021</dc:identifier><dc:identifier>10.11591/eei.v10i3.3021</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 3 (2021); 1164-1172</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3021/2159</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>