Demand response (DR) program through tariff initiative has been established in Malaysia since 1990. The available time of use (TOU) tariff focuses on providing price signals to consumers, especially from industrial and commercial sectors. In achieving a certain standard for off-peak tariff rider (OPTR) initiative to receive discount rate, consumers must improve load factors compared to the baseline declared. However, not all consumers are able to commit. In Universiti Teknikal Malaysia Melaka (UTeM), the TOU (C1-OPTR) tariff is proposed and applied when the available cost discount of 20% can be enjoyed by sustaining the load factor improvement (LFI). A simulator projected a flexible optimal load profile referred by the energy management team to achieve the university's sustainable energy management goal. Thus, securing the LFI would allow the energy consumption (kWh) and peak demand (kW) to be managed concurrently. As for testing results for two buildings, the load factor improves to 0.40, and the maximum demand reduces by about 35 kW. When getting the 20% discount for the OPTR scheme, the total cost saving is forecasted approximately USD 29,441.40 yearly. The current pilot project presents a positive sign with the peak demand reduction and load factor improvement close to the simulator's optimal profile.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 145 tautan kepenulisan bersama · 30 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Teknologi MARA
  • Universiti Malaysia Perlis
  • University of Technology Malaysia
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Universitas Ahmad Dahlan
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Elia Erwani HassanUniversiti Teknikal Malaysia Melaka4
Arfah AhmadUniversiti Teknikal Malaysia Melaka4
Nazrulazhar BahamanUniversiti Teknikal Malaysia Melaka3
Nurul Fasihah JumideyUniversiti Teknikal Malaysia Melaka3
Mustafah Mohd TahirUniversiti Teknikal Malaysia Melaka3
Zul Hasrizal BohariUniversiti Teknikal Malaysia Melaka2
Tarmizi Ahmad IzzuddinUniversiti Teknikal Malaysia Melaka2
Marizan SulaimanUniversiti Teknikal Malaysia Melaka2
Noor Ropidah BujalUniversiti Teknikal Malaysia Melaka2
Sulastri Abdul ManapUniversiti Malaysia Pahang Al-Sultan Abdullah2
Leong Lek ChungUniversiti Teknikal Malaysia Melaka2
Sharizad SaharaniUniversiti Teknikal Malaysia Melaka1
Mohd Ruzaini HashimUniversiti Teknikal Malaysia Melaka1
Hanan Izzati Mohd NoorUniversiti Teknikal Malaysia Melaka1
Haslenda binti HashimUniversity of Technology Malaysia1
Humam NazirUniversiti Teknikal Malaysia Melaka1
Nur Izyan ZulkafliUniversiti Teknikal Malaysia Melaka1
Mohd Hafiz JaliUniversiti Teknikal Malaysia Melaka1
Nur Saleha JayiddinAfiliasi tidak diketahui1
Azmi Md LasinAfiliasi tidak diketahui1
M Tarmidzi IskandarAfiliasi tidak diketahui1
Nofri Yenita DahlanUniversiti Teknologi MARA1
Zuhaila Mat YasinUniversiti Teknologi MARA1
Md Nazri OthmanUniversiti Teknikal Malaysia Melaka1
Hyreil Anuar KasdirinUniversiti Teknikal Malaysia Melaka1
Mohamed Hafiz bin Md IsaUniversiti Teknikal Malaysia Melaka1
Tole SutiknoUniversitas Ahmad Dahlan1
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka1
Rozaimi GhazaliUniversiti Teknikal Malaysia Melaka1
Mohamad Aqil Mohd FuadUniversiti Teknikal Malaysia Melaka1
Zanariah JanoUniversiti Teknikal Malaysia Melaka1
Muzamir IsaUniversiti Malaysia Perlis1
Ahmad Zaidi AbdullahUniversiti Malaysia Perlis1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimal load management strategy under off-peak tariff riders in UTeM: a case study</dc:title><dc:creator>Mohamad Fani Sulaima</dc:creator><dc:creator>Musthafah Mohd Tahir</dc:creator><dc:creator>Mohamad Firdaus Sukri</dc:creator><dc:creator>Aida Fazliana Abdul Kadir</dc:creator><dc:creator>Ainuddin Abu Kasim</dc:creator><dc:creator>Mohd Rahimi Yusoff</dc:creator><dc:creator>Luqman Ali</dc:creator><dc:subject>demand response</dc:subject><dc:subject>time-of-use pricing</dc:subject><dc:subject>peak shaving</dc:subject><dc:subject>load management</dc:subject><dc:subject>energy cost reduction</dc:subject><dc:subject>campus energy management</dc:subject><dc:description xml:lang="en">Demand response (DR) program through tariff initiative has been established in Malaysia since 1990. The available time of use (TOU) tariff focuses on providing price signals to consumers, especially from industrial and commercial sectors. In achieving a certain standard for off-peak tariff rider (OPTR) initiative to receive discount rate, consumers must improve load factors compared to the baseline declared. However, not all consumers are able to commit. In Universiti Teknikal Malaysia Melaka (UTeM), the TOU (C1-OPTR) tariff is proposed and applied when the available cost discount of 20% can be enjoyed by sustaining the load factor improvement (LFI). A simulator projected a flexible optimal load profile referred by the energy management team to achieve the university's sustainable energy management goal. Thus, securing the LFI would allow the energy consumption (kWh) and peak demand (kW) to be managed concurrently. As for testing results for two buildings, the load factor improves to 0.40, and the maximum demand reduces by about 35 kW. When getting the 20% discount for the OPTR scheme, the total cost saving is forecasted approximately USD 29,441.40 yearly. The current pilot project presents a positive sign with the peak demand reduction and load factor improvement close to the simulator's optimal profile.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i2.3556</dc:identifier><dc:identifier>10.11591/eei.v11i2.3556</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 2 (2022); 646-657</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3556/2603</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>