Characterization of a compact low cost 6.5kV Cockcroft voltage multiplier

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 4 (2022) · hlm. 1789–1797

DOI
10.11591/eei.v11i4.3809
ISSN
2089-3191, 2302-9285
Terbit
2022-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Generation of high voltages is often necessary in Industrial, Medical, civilian and defense applications. One of the popular methods of generation of high voltage DC is using a Cockcroft voltage multiplier generator. Knowledge on characterization of the voltage multiplier circuit helps the designer to study the effect of various input parameters on output, saves lot of time and money. In this paper various methods of generation of high voltages, advantages and disadvantages of each method are discussed. Design of five stage voltage multiplier circuit, fabrication and characterization of the 6.5kV voltage multiplier generator are presented. Simulation was carried using PSPICE software under different load conditions. Effect on the output voltage, ripple voltage with different values of load, frequency was studied. Experiments were carried out on the proposed prototype model and validated by comparing the values obtained from experimentation with the simulation and theoretical values

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 11 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Visvesvaraya Technological University
  • Acharya Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Shreyas KarnickAfiliasi tidak diketahui1
Sanjay LakshminarayananAfiliasi tidak diketahui1
Prakash RAcharya Institute of Technology1
Manjunatha Babu PattabhiAfiliasi tidak diketahui1
Ozwin Dominic DsouzaAfiliasi tidak diketahui1
Madhava Rao JillellaVisvesvaraya Technological University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Characterization of a compact low cost 6.5kV Cockcroft voltage multiplier</dc:title><dc:creator>Madhu Palati</dc:creator><dc:creator>Prashanth Narayanappa Ananda</dc:creator><dc:subject>high voltage generation</dc:subject><dc:subject>high-voltage DC</dc:subject><dc:subject>output voltage</dc:subject><dc:subject>output voltage ripple</dc:subject><dc:subject>loading conditions</dc:subject><dc:subject>PSpice simulation</dc:subject><dc:subject>prototype fabrication</dc:subject><dc:description xml:lang="en">Generation of high voltages is often necessary in Industrial, Medical, civilian and defense applications. One of the popular methods of generation of high voltage DC is using a Cockcroft voltage multiplier generator. Knowledge on characterization of the voltage multiplier circuit helps the designer to study the effect of various input parameters on output, saves lot of time and money. In this paper various methods of generation of high voltages, advantages and disadvantages of each method are discussed. Design of five stage voltage multiplier circuit, fabrication and characterization of the 6.5kV voltage multiplier generator are presented. Simulation was carried using PSPICE software under different load conditions. Effect on the output voltage, ripple voltage with different values of load, frequency was studied. Experiments were carried out on the proposed prototype model and validated by comparing the values obtained from experimentation with the simulation and theoretical values</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i4.3809</dc:identifier><dc:identifier>10.11591/eei.v11i4.3809</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 4 (2022); 1789-1797</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3809/2813</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>