Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Synchronization control techniques for shunt active power filter: an overview

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 1 (2023) · hlm. 1–9

DOI
10.11591/eei.v12i1.4300
ISSN
2089-3191, 2302-9285
Terbit
2023-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The phase synchronization control technique of shunt active power filter (SAPF) is discussed in this article. Due to the harmful effects of harmonic currents on power systems, the issue of decreasing their effects has generated a lot of research. A SAPF is acknowledged as the most dependable instrument in this area. The SAPF will detects the current harmonics present in the power system and also generates and injects the corrective current mitigation in the power system to reduce the current harmonics. This implies that, aside from the capacity to create compensating current, it is more essential to ensure that the SAPF can work in phase with the operational power system so that the compensating current will properly injected. As a result, while constructing SAPF control algorithms, correct synchronisation techniques must be incorporated. In this article, the different types of phase synchronization approach have been discussed such as phase-locked loop (PLL), adaptive linear neuron (Adaline), and unit vector. The results of the study may be used as a guideline and source of information for determining the best method for synchronising SAPF with the associated power system.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 10 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Annamalai University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ramamoorthi RagunathanAfiliasi tidak diketahui2
Sarayu VunnamAnnamalai University1
M. VanithasriAnnamalai University1
Dharani Kumar NarneAnnamalai University1
T. A. Ramesh KumarAnnamalai University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Synchronization control techniques for shunt active power filter: an overview</dc:title><dc:creator>Chegudi Ranga Rao</dc:creator><dc:creator>Balamurugan Ramadoss</dc:creator><dc:creator>RamaKoteswara Rao Alla</dc:creator><dc:subject>shunt active power filter</dc:subject><dc:subject>phase synchronization</dc:subject><dc:subject>harmonic current compensation</dc:subject><dc:subject>phase-locked loop</dc:subject><dc:subject>ADALINE</dc:subject><dc:subject>power quality</dc:subject><dc:description xml:lang="en">The phase synchronization control technique of shunt active power filter (SAPF) is discussed in this article. Due to the harmful effects of harmonic currents on power systems, the issue of decreasing their effects has generated a lot of research. A SAPF is acknowledged as the most dependable instrument in this area. The SAPF will detects the current harmonics present in the power system and also generates and injects the corrective current mitigation in the power system to reduce the current harmonics. This implies that, aside from the capacity to create compensating current, it is more essential to ensure that the SAPF can work in phase with the operational power system so that the compensating current will properly injected. As a result, while constructing SAPF control algorithms, correct synchronisation techniques must be incorporated. In this article, the different types of phase synchronization approach have been discussed such as phase-locked loop (PLL), adaptive linear neuron (Adaline), and unit vector. The results of the study may be used as a guideline and source of information for determining the best method for synchronising SAPF with the associated power system.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i1.4300</dc:identifier><dc:identifier>10.11591/eei.v12i1.4300</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 1 (2023); 1-9</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4300/3047</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>