Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

THD analysis and small AC signal analysis of trans-Z-source and quasi-Z-source inverter for linear and non-linear load

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 6 (2023) · hlm. 3889–3900

DOI
10.11591/eei.v12i6.6597
ISSN
2089-3191, 2302-9285
Terbit
2023-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The paper primarily focuses on the ongoing research related to Z source inverter technologies (ZSITs) used in the transportation industry, particularly for electric vehicles (EVs) and hybrid electrical vehicles (HEVs). It analyzes various topologies of ZSITs based on their mode of operation, capacitor voltage stress during active states and non-active state operations, DC link voltage before inverter module and line to line output voltage across the load. The paper compares the conventional trans-z source and two port quasi-Z source inverter model networks for multiple parameters and derives mathematical equations for both linear and non-linear loads. Practical and theoretical calculations match when using a modulation index of M=0.85 and a duty ratio of 1.414. The result obtained in this paper indicates that the proposed solution is better in terms of reduction in total total harmonics distortions (THD) percentage of 18.14% during the transition condition. All the analysis has been carried out with MATLAB based Simulink model.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 9 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • REVA University
  • KIIT University
  • RajaRajeswari College of Engineering
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Manju Jayakumar RaghvinREVA University3
Manjula R. BharamagoudraREVA University3
Sarat Chandra SwainKIIT University1
Sanhita MishraKIIT University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">THD analysis and small AC signal analysis of trans-Z-source and quasi-Z-source inverter for linear and non-linear load</dc:title><dc:creator>Manish Bharat</dc:creator><dc:creator>ASR Murty</dc:creator><dc:creator>Ritesh Kumar Dash</dc:creator><dc:subject>Z-source inverter</dc:subject><dc:subject>quasi-Z-source inverter</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>capacitor voltage stress</dc:subject><dc:subject>DC bus voltage</dc:subject><dc:subject>electric vehicles</dc:subject><dc:subject>hybrid electric vehicles</dc:subject><dc:subject>inverter topology</dc:subject><dc:description xml:lang="en">The paper primarily focuses on the ongoing research related to Z source inverter technologies (ZSITs) used in the transportation industry, particularly for electric vehicles (EVs) and hybrid electrical vehicles (HEVs). It analyzes various topologies of ZSITs based on their mode of operation, capacitor voltage stress during active states and non-active state operations, DC link voltage before inverter module and line to line output voltage across the load. The paper compares the conventional trans-z source and two port quasi-Z source inverter model networks for multiple parameters and derives mathematical equations for both linear and non-linear loads. Practical and theoretical calculations match when using a modulation index of M=0.85 and a duty ratio of 1.414. The result obtained in this paper indicates that the proposed solution is better in terms of reduction in total total harmonics distortions (THD) percentage of 18.14% during the transition condition. All the analysis has been carried out with MATLAB based Simulink model.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i6.6597</dc:identifier><dc:identifier>10.11591/eei.v12i6.6597</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 6 (2023); 3889-3900</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6597/3509</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>