Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A simulation study of excitation coil design in single-sided mpi scanner for human body application

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 4 (2019)

DOI
10.11591/eei.v8i4.1597
ISSN
2089-3191, 2302-9285
Terbit
2019-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Magnetic particle imaging (MPI), a tomographic imaging method has been introduced for 3D imaging of human body with some potential applications such as magnetic hyperthermia and cancer imaging. It involves three important elements: tracer development using magnetic nanoparticles (MNPs), hardware realization (scanner using excitation and pickup coils), and image reconstruction optimization. Their combination will produce a high quality of image taken from any biological tissue in the human body based on the secondary magnetic field signal from the magnetized MNPs that are injected into human body. A homogeneous and adequate magnetic field strength from an excitation coil is needed to enhance the quality of the secondary signal. However, the complex surface topography of human body and physical properties of an excitation coil influence the strength and the homogeneity of the magnetic field generation at the MNPs. Therefore, this work focused on finding alternative design of excitation coil used in single sided MPI to produce up to 2 mT with high homogeneity of field distribution in the MNPs at the varied depth of 10 to 30 mm under the excitation coil. We proposed several designs with variation in physical properties and coil arrangement based on simulation study carried out by using Ansys Maxwell.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 97 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Norwahidah IbrahimTun Hussein Onn University of Malaysia5
Syadia Nabilah Mohd SafuanTun Hussein Onn University of Malaysia5
Mohd Norzali Haji MohdTun Hussein Onn University of Malaysia4
Nor Surayahani SurianiTun Hussein Onn University of Malaysia4
Cham Ying KitTun Hussein Onn University of Malaysia3
Jacqueline Ang Jie YiTun Hussein Onn University of Malaysia3
Nicholas Tan Chun ShengTun Hussein Onn University of Malaysia3
Muhammad Fuad bin KassimTun Hussein Onn University of Malaysia2
Suhaila SariTun Hussein Onn University of Malaysia2
M. S. KamarudinTun Hussein Onn University of Malaysia1
Nor Akmal Mohd JamailTun Hussein Onn University of Malaysia1
Nordiana Azlin OthmanTun Hussein Onn University of Malaysia1
Zainab ZainalTun Hussein Onn University of Malaysia1
Rahisham Abd RahmanTun Hussein Onn University of Malaysia1
Mohd Fairouz Mohd YousofTun Hussein Onn University of Malaysia1
Matiullah AhsanTun Hussein Onn University of Malaysia1
Omar Abu HassanTun Hussein Onn University of Malaysia1
Faridah HanimAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A simulation study of excitation coil design in single-sided mpi scanner for human body application</dc:title><dc:creator>Nurmiza Binti Othman</dc:creator><dc:creator>Muhamad Fikri Shahkhirin Birahim</dc:creator><dc:creator>Wan Nurshazwani Wan Zakaria</dc:creator><dc:creator>Razali Tomari</dc:creator><dc:creator>Md Nor Ramdon Baharom</dc:creator><dc:creator>Luqman Nol Hakim</dc:creator><dc:subject>magnetic particle imaging</dc:subject><dc:subject>magnetic field homogeneity</dc:subject><dc:subject>magnetic nanoparticles</dc:subject><dc:subject>human body imaging</dc:subject><dc:subject>coil configuration</dc:subject><dc:subject>magnetic field modeling</dc:subject><dc:subject>magnetic hyperthermia</dc:subject><dc:description xml:lang="en">Magnetic particle imaging (MPI), a tomographic imaging method has been introduced for 3D imaging of human body with some potential applications such as magnetic hyperthermia and cancer imaging. It involves three important elements: tracer development using magnetic nanoparticles (MNPs), hardware realization (scanner using excitation and pickup coils), and image reconstruction optimization. Their combination will produce a high quality of image taken from any biological tissue in the human body based on the secondary magnetic field signal from the magnetized MNPs that are injected into human body. A homogeneous and adequate magnetic field strength from an excitation coil is needed to enhance the quality of the secondary signal. However, the complex surface topography of human body and physical properties of an excitation coil influence the strength and the homogeneity of the magnetic field generation at the MNPs. Therefore, this work focused on finding alternative design of excitation coil used in single sided MPI to produce up to 2 mT with high homogeneity of field distribution in the MNPs at the varied depth of 10 to 30 mm under the excitation coil. We proposed several designs with variation in physical properties and coil arrangement based on simulation study carried out by using Ansys Maxwell.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i4.1597</dc:identifier><dc:identifier>10.11591/eei.v8i4.1597</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 4 (2019)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1597/1204</dc:relation></oai_dc:dc>