This paper aims to evaluate the photovoltaic (PV) nanogrid implementation and its risk for a project at a remote location. Unlike the normal approach, this approach is based on a discontinuity project. The main advantage of the model is the simplicity to compute the expected lifetime and display the reliability curve. The reliability is calculated using state space equation and a quantitative approach evaluates the risk of PV nanogrid scenarios based on costs. The MATLAB/Simulink simulates the scenarios including the basic scenario of a PV system that is a PV nanogrid consisting of a PV array and inverter, scenario 1 that is a PV nanogrid with a battery system, scenario 2 is an extension of scenario 1 with a battery repair, and scenario 3 is a PV nanogrid connected to the grid. The result indicates that adding a battery system increases the reliability and the expected lifetime of the system, and the battery system’s maintenance makes it higher. Scenario 3 shows high reliability and a longer expected lifetime. The risk matrix shows the position of reliability and its impact on each scenario. This work can be used in practice as an objective assessment to electrify frontier, remote, and disadvantaged (3T) areas beside levelized cost of energy (LCOE).
Jaringan kolaborasi para penulis
8 penulis ·
12 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology State University of Semarang
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparison of photovoltaic nanogrid implementation: a simple reliability model for frontier, remote, and disadvantaged areas</dc:title><dc:creator>Ryandi Ryandi</dc:creator><dc:creator>Kevin Marojahan Banjar-Nahor</dc:creator><dc:creator>Nanang Hariyanto</dc:creator><dc:subject>reliability modeling</dc:subject><dc:subject>life expectancy</dc:subject><dc:subject>state-space model</dc:subject><dc:subject>battery energy storage</dc:subject><dc:subject>battery maintenance</dc:subject><dc:subject>grid connection</dc:subject><dc:subject>remote area electrification</dc:subject><dc:subject>risk assessment</dc:subject><dc:subject>risk matrix</dc:subject><dc:subject>levelized cost of electricity</dc:subject><dc:subject>inverter</dc:subject><dc:description xml:lang="en">This paper aims to evaluate the photovoltaic (PV) nanogrid implementation and its risk for a project at a remote location. Unlike the normal approach, this approach is based on a discontinuity project. The main advantage of the model is the simplicity to compute the expected lifetime and display the reliability curve. The reliability is calculated using state space equation and a quantitative approach evaluates the risk of PV nanogrid scenarios based on costs. The MATLAB/Simulink simulates the scenarios including the basic scenario of a PV system that is a PV nanogrid consisting of a PV array and inverter, scenario 1 that is a PV nanogrid with a battery system, scenario 2 is an extension of scenario 1 with a battery repair, and scenario 3 is a PV nanogrid connected to the grid. The result indicates that adding a battery system increases the reliability and the expected lifetime of the system, and the battery system’s maintenance makes it higher. Scenario 3 shows high reliability and a longer expected lifetime. The risk matrix shows the position of reliability and its impact on each scenario. This work can be used in practice as an objective assessment to electrify frontier, remote, and disadvantaged (3T) areas beside levelized cost of energy (LCOE).</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i5.3814</dc:identifier><dc:identifier>10.11591/eei.v11i5.3814</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 5 (2022); 2399-2405</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3814/2881</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ryandi, R., Banjar-Nahor, K. M., & Hariyanto, N. (2022). Comparison of photovoltaic nanogrid implementation: a simple reliability model for frontier, remote, and disadvantaged areas. Bulletin of Electrical Engineering and Informatics, 11(5), 2399–2405. https://doi.org/10.11591/eei.v11i5.3814
Salin
IEEE
R. Ryandi, K. M. Banjar-Nahor, and N. Hariyanto, “Comparison of photovoltaic nanogrid implementation: a simple reliability model for frontier, remote, and disadvantaged areas,” Bulletin of Electrical Engineering and Informatics, vol. 11, no. 5, pp. 2399–2405, 2022, doi: 10.11591/eei.v11i5.3814.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.