Akses terbuka
Jurnal
SINTA 1
Improved bidirectional long short term memory-based QRS complex detection using autoencoder
Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 4 (2024) · hlm. 2508–2516
ISSN 2089-3191, 2302-9285
Terbit 2024-08-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
In this paper, we propose a new technique to improve QRS complex detection. This technique consists of incorporating an autoencoder and bidirectional long short term memory (BiLSTM). The autoencoder used is a stacked autoencoder and functions as signal filtering. Meanwhile, BiLSTM is used as a detector. Exploration of the effect of hyperparameter in the autoencoder was also carried out to determine the effect on QRS complex detection. Furthermore, the dataset used in this study is the MIT-BIH arrhythmia database. Based on the experimental results, the hyperparameter in the autoencoder that gives a better effect on QRS complex detection is 16-8. Finally, the proposed method out-of-perform state of the art algorithm with accuracy 99.94%.
Jaringan kolaborasi para penulis
3 penulis ·
2 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Telkom University National Research and Innovation Agency
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Improved bidirectional long short term memory-based QRS complex detection using autoencoder</dc:title><dc:creator>Asep Insani</dc:creator><dc:creator>Suryo Adhi Wibowo</dc:creator><dc:subject>QRS complex detection</dc:subject><dc:subject>bidirectional LSTM</dc:subject><dc:subject>stacked autoencoder</dc:subject><dc:subject>signal denoising</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>MIT-BIH arrhythmia database</dc:subject><dc:subject>hyperparameter optimization</dc:subject><dc:subject>ECG signal processing</dc:subject><dc:description xml:lang="en">In this paper, we propose a new technique to improve QRS complex detection. This technique consists of incorporating an autoencoder and bidirectional long short term memory (BiLSTM). The autoencoder used is a stacked autoencoder and functions as signal filtering. Meanwhile, BiLSTM is used as a detector. Exploration of the effect of hyperparameter in the autoencoder was also carried out to determine the effect on QRS complex detection. Furthermore, the dataset used in this study is the MIT-BIH arrhythmia database. Based on the experimental results, the hyperparameter in the autoencoder that gives a better effect on QRS complex detection is 16-8. Finally, the proposed method out-of-perform state of the art algorithm with accuracy 99.94%.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i4.7033</dc:identifier><dc:identifier>10.11591/eei.v13i4.7033</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 4 (2024); 2508-2516</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7033/3796</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Insani, A., & Wibowo, S. A. (2024). Improved bidirectional long short term memory-based QRS complex detection using autoencoder. Bulletin of Electrical Engineering and Informatics, 13(4), 2508–2516. https://doi.org/10.11591/eei.v13i4.7033
Salin
IEEE
A. Insani and S. A. Wibowo, “Improved bidirectional long short term memory-based QRS complex detection using autoencoder,” Bulletin of Electrical Engineering and Informatics, vol. 13, no. 4, pp. 2508–2516, 2024, doi: 10.11591/eei.v13i4.7033.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.