Abstrak

Silicone rubber (SiR) has become a reliable choice for outdoor high voltage (HV) insulation in recent years. However, the durability of these polymeric materials is affected by both electrical and environmental stresses, leading to aging. While prior research aimed at enhancing performance, little focus was placed on identifying the major root causes of aging in these insulators. To delve into the causes, we conducted inclined plane tracking (IPT) tests, varying voltage, flow rate, and contamination concentration. Samples with consistent alumina trihydrate (ATH) filler content were tested under the BSEN 60587 standard. The voltage ranged from 3.5-5.5 kV, flow rate from 0.3-0.9 ml/min, and contamination concentration from 500-4500 µS/cm. A Two-Level Factorial analysis with a design of experiment (DOE) approach was used. The study revealed that contaminant concentration significantly impacted leakage current (LC), followed by contamination flow rate and voltage. Additionally, optimization techniques are used to determine ideal LC values under specific conditions. This study explains how each factor affects LC values, allowing for predictive modelling, which improves our understanding of SiR insulators' durability, optimizes LC in real-world situations, and improves their performance and lifespan.

Kata kunci

Jaringan kolaborasi para penulis

35 penulis · 105 tautan kepenulisan bersama · 42 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • State University of Malang
  • Tun Hussein Onn University of Malaysia
  • Universitas Muhammadiyah Riau
  • Limkokwing University of Creative Technology
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • University of Technology Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Imran Sutan ChairulUniversiti Teknikal Malaysia Melaka6
Rahisham Abd RahmanTun Hussein Onn University of Malaysia5
Sharin Ab GhaniUniversiti Teknikal Malaysia Melaka4
Mohd Safwan MohamadUniversiti Teknikal Malaysia Melaka2
Zahriladha ZakariaUniversiti Teknikal Malaysia Melaka2
Mohd Muzafar IsmailUniversiti Teknikal Malaysia Melaka2
Nor Hadzfizah Mohd RadiUniversiti Malaysia Pahang Al-Sultan Abdullah2
M. S. KamarudinTun Hussein Onn University of Malaysia2
Ayuamira ZahariUniversiti Teknikal Malaysia Melaka2
Jamaludin Mohd WariAfiliasi tidak diketahui2
Nur Amirah OthmanUniversiti Teknikal Malaysia Melaka1
Aminuddin AmanUniversiti Teknikal Malaysia Melaka1
Sharin Abd GhaniAfiliasi tidak diketahui1
Nor Asiah MuhamadUniversiti Sains Malaysia1
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia1
Muhammad Ilman Hakimi Chua AbdullahUniversiti Teknikal Malaysia Melaka1
Muhamad Hafiy Syazwan ZainoddinUniversiti Teknikal Malaysia Melaka1
Aminudin AmanUniversiti Teknikal Malaysia Melaka1
Mohd Fairouz Mohd YousofTun Hussein Onn University of Malaysia1
Nurul Farahwahida Md YasidTun Hussein Onn University of Malaysia1
Poppy PuspitasariState University of Malang1
Avita Ayu PermanasariState University of Malang1
Diki Dwi PramonoState University of Malang1
Dany Ardymas KurniawanState University of Malang1
Ahmad Atif FikriState University of Malang1
Budi IstanaUniversitas Muhammadiyah Riau1
AdriyanUniversitas Muhammadiyah Riau1
Agus MulyadiUniversitas Muhammadiyah Riau1
Cici MaarasyidUniversitas Muhammadiyah Riau1
Siti Nur Illia AbdullahUniversiti Teknikal Malaysia Melaka1
S. R. Ab RashidUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Ageing durability of SiR under prolonged voltage stress, contaminant flow and contaminant concentration: a statistical approach</dc:title><dc:creator>Nornazurah Nazir Ali</dc:creator><dc:creator>Hidayat Zainuddin</dc:creator><dc:creator>Jeefferie Abd Razak</dc:creator><dc:creator>Nur Farhani Ambo</dc:creator><dc:subject>silicone rubber</dc:subject><dc:subject>electrical aging</dc:subject><dc:subject>leakage current</dc:subject><dc:subject>pollutant concentration</dc:subject><dc:subject>voltage stress</dc:subject><dc:subject>durability</dc:subject><dc:subject>experimental design</dc:subject><dc:subject>factorial analysis</dc:subject><dc:subject>predictive modeling</dc:subject><dc:description xml:lang="en">Silicone rubber (SiR) has become a reliable choice for outdoor high voltage (HV) insulation in recent years. However, the durability of these polymeric materials is affected by both electrical and environmental stresses, leading to aging. While prior research aimed at enhancing performance, little focus was placed on identifying the major root causes of aging in these insulators. To delve into the causes, we conducted inclined plane tracking (IPT) tests, varying voltage, flow rate, and contamination concentration. Samples with consistent alumina trihydrate (ATH) filler content were tested under the BSEN 60587 standard. The voltage ranged from 3.5-5.5 kV, flow rate from 0.3-0.9 ml/min, and contamination concentration from 500-4500 µS/cm. A Two-Level Factorial analysis with a design of experiment (DOE) approach was used. The study revealed that contaminant concentration significantly impacted leakage current (LC), followed by contamination flow rate and voltage. Additionally, optimization techniques are used to determine ideal LC values under specific conditions. This study explains how each factor affects LC values, allowing for predictive modelling, which improves our understanding of SiR insulators' durability, optimizes LC in real-world situations, and improves their performance and lifespan.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v13i5.8141</dc:identifier><dc:identifier>10.11591/eei.v13i5.8141</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 5 (2024); 3051-3059</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>