Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Solar photovoltaic integrated load frequency control of power system using variable structure fuzzy controller

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 6 (2024) · hlm. 3800–3808

DOI
10.11591/eei.v13i6.7806
ISSN
2089-3191, 2302-9285
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The incorporation of renewable energy sources into modern power systems is on the upswing, intending to produce and deliver cost-efficient electricity to meet the ever-increasing demands of today’s world. Solar energy stands out as a plentiful and robust solution for meeting current electricity requirements. However, integrating solar photovoltaic (PV) generated power into the contemporary power system introduces complexity, necessitating the development of suitable control design to ensure effective regulation of load frequency control (LFC). This research paper concentrates on the mathematical modeling and integration of solar PV generated electricity into a hydrothermal system. In addition, this study also evaluates the performance of the variable structure fuzzy (VSF) control with reduced rule base for hydrothermal system concerning varying degrees of disturbances in one or in both regions of the power system. Moreover, the research reveals that the integration of PV power into hydro-thermal systems can improve the LFC outputs and mitigate system deviations in the face of different disturbance scenarios.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Durban University of Technology
  • Mangosuthu University of Technology
  • Manipal Academy of Higher Education
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kabulo LojiDurban University of Technology2
Musasa KabeyaDurban University of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Solar photovoltaic integrated load frequency control of power system using variable structure fuzzy controller</dc:title><dc:creator>S.B. Masikana</dc:creator><dc:creator>Gulshan Sharma</dc:creator><dc:creator>Sachin Sharma</dc:creator><dc:subject>photovoltaic integration</dc:subject><dc:subject>load frequency control</dc:subject><dc:subject>hydrothermal power systems</dc:subject><dc:subject>renewable energy integration</dc:subject><dc:subject>frequency regulation</dc:subject><dc:subject>disturbance rejection</dc:subject><dc:subject>power system control</dc:subject><dc:description xml:lang="en">The incorporation of renewable energy sources into modern power systems is on the upswing, intending to produce and deliver cost-efficient electricity to meet the ever-increasing demands of today’s world. Solar energy stands out as a plentiful and robust solution for meeting current electricity requirements. However, integrating solar photovoltaic (PV) generated power into the contemporary power system introduces complexity, necessitating the development of suitable control design to ensure effective regulation of load frequency control (LFC). This research paper concentrates on the mathematical modeling and integration of solar PV generated electricity into a hydrothermal system. In addition, this study also evaluates the performance of the variable structure fuzzy (VSF) control with reduced rule base for hydrothermal system concerning varying degrees of disturbances in one or in both regions of the power system. Moreover, the research reveals that the integration of PV power into hydro-thermal systems can improve the LFC outputs and mitigate system deviations in the face of different disturbance scenarios.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i6.7806</dc:identifier><dc:identifier>10.11591/eei.v13i6.7806</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 6 (2024); 3800-3808</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7806/4009</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>