Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Residual pixel-wise semantic segmentation for assessing enlarged fetal heart: a preliminary study

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 4 (2025) · hlm. 2684–2696

DOI
10.11591/eei.v14i4.9244
ISSN
2089-3191, 2302-9285
Terbit
2025-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The four-chamber view is a crucial scan plane routinely employed in both second-trimester perinatal screening and fetal echocardiographic examinations. Sonographers typically measure biometrics in this plane, such as the cardiothoracic ratio (CTR) and heart axis, to diagnose fetal heart anomalies. However, due to the echocardiographic artifacts, the assessment not only suffers from low efficiency but also inconsistent results depending on the operators’ skills. This study proposes a residual pixel-wise semantic segmentation, which segmented the fetal heart and thoracic contours in a 4-chamber view for assessing an enlarged fetal heart condition. The accuracy of intersection-over-union (IoU) and dice coefficient similarity (DCS) is used for model validation to further regulate the evaluation procedure. We use 1174 US images, comprising about 560 enlarged heart images, and about 614 normal heart images. Out of these data, 248 images are used for unseen data, and the remaining for training/validation processes. The performance of the proposed model, when tested on unseen data, achieved satisfactory results with 97.71% accuracy, 90.36% IoU, and 94.93% DCS. These metrics collectively demonstrate the satisfactory performance of the proposed model compared to existing segmentation models. The outcomes underscore that the proposed model establishes a state-of-the-art standard for enlarged fetal heart detection.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 193 tautan kepenulisan bersama · 23 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sriwijaya University
  • Politeknik Negeri Sriwijaya
  • Bandung Institute of Technology
  • Institut Teknologi dan Sains Nahdlatul Ulama
  • Universitas Islam Negeri Imam Bonjol Padang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bambang TutukoSriwijaya University27
Firdaus FirdausSriwijaya University23
Anggun IslamiSriwijaya University16
Sukemi SukemiSriwijaya University9
Muhammad FachrurroziSriwijaya University8
Akhiar Wista ArumSriwijaya University8
Samsuryadi SamsuryadiSriwijaya University6
Jordan MarcelinoSriwijaya University6
Rendy IsdwantaSriwijaya University6
Radiyati Umi PartanSriwijaya University4
Ghita AthalinaAfiliasi tidak diketahui4
Muhammad Alpim Alfa RolisAfiliasi tidak diketahui4
Firdaus FirdausUniversitas Islam Negeri Imam Bonjol Padang4
Sutarno SutarnoSriwijaya University4
Novi YuslianiSriwijaya University4
Renny Amalia PratiwiSriwijaya University4
Nuswil BernolianAfiliasi tidak diketahui4
Winda Kurnia SariSriwijaya University3
Nyayu Latifah HusniBandung Institute of Technology2
Irsyadi YaniSriwijaya University2
Ade SilviaBandung Institute of Technology2
Bhakti Yudho SupraptoSriwijaya University2
Deris StiawanSriwijaya University2
Tresna DewiPoliteknik Negeri Sriwijaya1
Pola RismaPoliteknik Negeri Sriwijaya1
Yurni OktarinaPoliteknik Negeri Sriwijaya1
Muhammad RorizPoliteknik Negeri Sriwijaya1
Erliza YuniartiSriwijaya University1
Tri Kurnia SariAfiliasi tidak diketahui1
Rossi PassarellaSriwijaya University1
Jerrel Adriel Archibald HutahaeanSriwijaya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Residual pixel-wise semantic segmentation for assessing enlarged fetal heart: a preliminary study</dc:title><dc:creator>Muhammad Taufik Roseno</dc:creator><dc:creator>Siti Nurmaini</dc:creator><dc:creator>Dian Palupi Rini</dc:creator><dc:creator>Tommy Saputra</dc:creator><dc:creator>Putri Mirani</dc:creator><dc:creator>Muhammad Naufal Rachmatullah</dc:creator><dc:creator>Annisa Darmawahyuni</dc:creator><dc:creator>Ade Iriani Sapitri</dc:creator><dc:creator>Hadi Syaputra</dc:creator><dc:subject>fetal echocardiography</dc:subject><dc:subject>four-chamber view</dc:subject><dc:subject>ultrasound image segmentation</dc:subject><dc:subject>cardiothoracic ratio</dc:subject><dc:description xml:lang="en">The four-chamber view is a crucial scan plane routinely employed in both second-trimester perinatal screening and fetal echocardiographic examinations. Sonographers typically measure biometrics in this plane, such as the cardiothoracic ratio (CTR) and heart axis, to diagnose fetal heart anomalies. However, due to the echocardiographic artifacts, the assessment not only suffers from low efficiency but also inconsistent results depending on the operators’ skills. This study proposes a residual pixel-wise semantic segmentation, which segmented the fetal heart and thoracic contours in a 4-chamber view for assessing an enlarged fetal heart condition. The accuracy of intersection-over-union (IoU) and dice coefficient similarity (DCS) is used for model validation to further regulate the evaluation procedure. We use 1174 US images, comprising about 560 enlarged heart images, and about 614 normal heart images. Out of these data, 248 images are used for unseen data, and the remaining for training/validation processes. The performance of the proposed model, when tested on unseen data, achieved satisfactory results with 97.71% accuracy, 90.36% IoU, and 94.93% DCS. These metrics collectively demonstrate the satisfactory performance of the proposed model compared to existing segmentation models. The outcomes underscore that the proposed model establishes a state-of-the-art standard for enlarged fetal heart detection.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i4.9244</dc:identifier><dc:identifier>10.11591/eei.v14i4.9244</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 4 (2025); 2684-2696</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9244/4280</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>