Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Improved power quality and reduced losses in DFIG-based WECS using third-order sliding mode control

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 6 (2025) · hlm. 4198–4207

DOI
10.11591/eei.v14i6.9634
ISSN
2089-3191, 2302-9285
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The study presents a comparative analysis of two advanced high-order sliding mode control (HOSMC) strategies—super-twisting sliding mode control (STSMC) and third-order sliding mode control (TOSMC)—for enhancing the performance of doubly-fed induction generator (DFIG)-based wind energy conversion systems (WECS). The key goals are to maximize energy efficiency, minimize the total harmonic distortion (THD) in the stator current, and reduce electrical losses within the system. Both control strategies are integrated into a direct field-oriented control (DFOC) scheme using space vector modulation (SVM) to improve dynamic response and control accuracy. MATLAB/Simulink simulations show that TOSMC consistently outperforms STSMC in multiple performance aspects. TOSMC ensures better energy efficiency through precise tracking of active and reactive power references while mitigating transient oscillations (chattering effects).Furthermore, TOSMC significantly reduces harmonic distortion, achieving a THD of 0.21%, compared to 0.33% for STSMC, and surpasses conventional controllers, which exhibit a minimum recorded THD of approximately 0.46%. The mitigation of transient phenomena also contributes to reduced switching losses and ohmic heating, thereby enhancing the generator’s thermal stability and overall reliability.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université Larbi Tébessi
  • Badji Mokhtar-Annaba University
  • Ziane Achour University of Djelfa
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mebarka BayoudBadji Mokhtar-Annaba University1
Belgacem Mohamed Nassim BouzidiZiane Achour University of Djelfa1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Improved power quality and reduced losses in DFIG-based WECS using third-order sliding mode control</dc:title><dc:creator>Abdelaziz Belhait</dc:creator><dc:creator>Messaoud Louafi</dc:creator><dc:creator>Sihem Ghoudelbourk</dc:creator><dc:subject>third-order sliding mode control</dc:subject><dc:subject>super-twisting sliding mode control</dc:subject><dc:subject>doubly fed induction generator</dc:subject><dc:subject>wind energy conversion system</dc:subject><dc:subject>power quality</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>power losses</dc:subject><dc:subject>direct field oriented control</dc:subject><dc:subject>space vector modulation</dc:subject><dc:subject>active and reactive power tracking</dc:subject><dc:subject>chattering reduction</dc:subject><dc:subject>switching losses</dc:subject><dc:description xml:lang="en">The study presents a comparative analysis of two advanced high-order sliding mode control (HOSMC) strategies—super-twisting sliding mode control (STSMC) and third-order sliding mode control (TOSMC)—for enhancing the performance of doubly-fed induction generator (DFIG)-based wind energy conversion systems (WECS). The key goals are to maximize energy efficiency, minimize the total harmonic distortion (THD) in the stator current, and reduce electrical losses within the system. Both control strategies are integrated into a direct field-oriented control (DFOC) scheme using space vector modulation (SVM) to improve dynamic response and control accuracy. MATLAB/Simulink simulations show that TOSMC consistently outperforms STSMC in multiple performance aspects. TOSMC ensures better energy efficiency through precise tracking of active and reactive power references while mitigating transient oscillations (chattering effects).Furthermore, TOSMC significantly reduces harmonic distortion, achieving a THD of 0.21%, compared to 0.33% for STSMC, and surpasses conventional controllers, which exhibit a minimum recorded THD of approximately 0.46%. The mitigation of transient phenomena also contributes to reduced switching losses and ohmic heating, thereby enhancing the generator’s thermal stability and overall reliability.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i6.9634</dc:identifier><dc:identifier>10.11591/eei.v14i6.9634</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 6 (2025); 4198-4207</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9634/4446</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>