Akses terbuka
Jurnal
SINTA 1
PID controller tuning performance evaluation based on integral time square error for coupled tank system
Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 1 (2026) · hlm. 875–883
ISSN 2089-3191, 2302-9285
Terbit 2026-02-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This study presents a conclusive performance evaluation based on integral time between the conventional and optimization based proportional integral derivatives (PID) tuning method. The tuning method of interest are including trial and error, auto-tuning, Ziegler-Nichols (ZN), Cohen-Coon (CC), and particle swarm optimization (PSO). The coupled tank system (CTS) is used for the system under consideration as it’s one of the popular technologies in industrial control application. Previous study had compared the tuning performance in terms of its transient response. The transient consists of several parameters such as rise time (Tr), settling time (Ts), peak time (Tp), steady state error, overshoot, and steady state error. Due to that, a conclusive performance comparison could not be achieved. Hence this study proposed integral time squared error evolution which is based on only one parameter which also reflects good overall transient response performance. The results show that of all tuning methods, PSO provide the smallest integral time square error (ITSE) value, while trial and error provide the highest with a value of 12.84 and 203.10, respectively. The ITSE also reflects the transient response performances.
Jaringan kolaborasi para penulis
17 penulis ·
44 tautan kepenulisan bersama
· 15 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universiti Teknikal Malaysia Melaka Sultan Idris Education University Universiti Teknologi Petronas Universiti Teknologi MARA Atatürk University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">PID controller tuning performance evaluation based on integral time square error for coupled tank system</dc:title><dc:creator>Nur Asmiza Selamat</dc:creator><dc:creator>Atikah Binti Razi</dc:creator><dc:creator>Syahar Azalia Ab Shukor</dc:creator><dc:creator>Nur Hazahsha Shamsudin</dc:creator><dc:creator>Fardila Mohd Zaihidee</dc:creator><dc:subject>PID controller tuning</dc:subject><dc:subject>coupled tank system</dc:subject><dc:subject>integral time squared error</dc:subject><dc:subject>transient response</dc:subject><dc:subject>particle swarm optimization</dc:subject><dc:subject>Ziegler-Nichols tuning</dc:subject><dc:subject>Cohen-Coon tuning</dc:subject><dc:subject>auto-tuning</dc:subject><dc:subject>trial and error tuning</dc:subject><dc:subject>performance evaluation</dc:subject><dc:description xml:lang="en">This study presents a conclusive performance evaluation based on integral time between the conventional and optimization based proportional integral derivatives (PID) tuning method. The tuning method of interest are including trial and error, auto-tuning, Ziegler-Nichols (ZN), Cohen-Coon (CC), and particle swarm optimization (PSO). The coupled tank system (CTS) is used for the system under consideration as it’s one of the popular technologies in industrial control application. Previous study had compared the tuning performance in terms of its transient response. The transient consists of several parameters such as rise time (Tr), settling time (Ts), peak time (Tp), steady state error, overshoot, and steady state error. Due to that, a conclusive performance comparison could not be achieved. Hence this study proposed integral time squared error evolution which is based on only one parameter which also reflects good overall transient response performance. The results show that of all tuning methods, PSO provide the smallest integral time square error (ITSE) value, while trial and error provide the highest with a value of 12.84 and 203.10, respectively. The ITSE also reflects the transient response performances.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.9334</dc:identifier><dc:identifier>10.11591/eei.v15i1.9334</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 875-883</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9334/4619</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Selamat, N. A., Razi, A. B., Shukor, S. A. A., Shamsudin, N. H., & Zaihidee, F. M. (2026). PID controller tuning performance evaluation based on integral time square error for coupled tank system. Bulletin of Electrical Engineering and Informatics, 15(1), 875–883. https://doi.org/10.11591/eei.v15i1.9334
Salin
IEEE
N. A. Selamat, A. B. Razi, S. A. A. Shukor, N. H. Shamsudin, and F. M. Zaihidee, “PID controller tuning performance evaluation based on integral time square error for coupled tank system,” Bulletin of Electrical Engineering and Informatics, vol. 15, no. 1, pp. 875–883, 2026, doi: 10.11591/eei.v15i1.9334.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.