This article examines a novel control technique known as the fractional order integral-tilt derivative (FOI-TD) controller, which was used for automatic generation control (AGC) with a two-area restructured power system. The FOI-TD controller enhances performance by integrating tilt- derivative control with fractional-order control. Fractional-order control offers greater flexibility and allows for more precise tuning of the controller's response. The tilt component modifying the proportional term minimizes overshoot and improves settling times. The control parameters of the FOI-TD controller are optimized using the moth flame optimization (MFO) method and the efficacy of the given algorithm is associated with recent studies using meta-heuristic techniques. Analysis indicates that the MFO-optimized FOI-TD controller substantially enhances the dynamic response of the AGC loop and compared with traditional controllers. This enhancement includes reduced peak deviations, shorter settling times, and better suppression of area frequencies and tie-line power oscillations across different transaction scenarios within restructured power system. To further enhance AGC performance, fast-acting energy storage systems, like sodium- ion batteries (SIB), are integrated into the control area. The coordinated operation of the SIB units improves system dynamics and stability by mitigating initial frequency drops and tie-line power variations caused by sudden load disturbances.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Annamalai University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimized FOI-TD controller for automatic generation control of restructured power systems with sodium-ion batteries</dc:title><dc:creator>Nanthini B S</dc:creator><dc:creator>IlanjiAkilandam Chidambaram</dc:creator><dc:creator>Rajeswaran Sivasangari</dc:creator><dc:subject>automatic generation control</dc:subject><dc:subject>moth-flame optimization</dc:subject><dc:subject>sodium-ion batteries</dc:subject><dc:subject>power system restructuring</dc:subject><dc:subject>two-area power system</dc:subject><dc:subject>tie-line power oscillations</dc:subject><dc:subject>frequency deviation</dc:subject><dc:subject>energy storage coordination</dc:subject><dc:subject>load disturbance</dc:subject><dc:subject>metaheuristic controller tuning</dc:subject><dc:description xml:lang="en">This article examines a novel control technique known as the fractional order integral-tilt derivative (FOI-TD) controller, which was used for automatic generation control (AGC) with a two-area restructured power system. The FOI-TD controller enhances performance by integrating tilt- derivative control with fractional-order control. Fractional-order control offers greater flexibility and allows for more precise tuning of the controller's response. The tilt component modifying the proportional term minimizes overshoot and improves settling times. The control parameters of the FOI-TD controller are optimized using the moth flame optimization (MFO) method and the efficacy of the given algorithm is associated with recent studies using meta-heuristic techniques. Analysis indicates that the MFO-optimized FOI-TD controller substantially enhances the dynamic response of the AGC loop and compared with traditional controllers. This enhancement includes reduced peak deviations, shorter settling times, and better suppression of area frequencies and tie-line power oscillations across different transaction scenarios within restructured power system. To further enhance AGC performance, fast-acting energy storage systems, like sodium- ion batteries (SIB), are integrated into the control area. The coordinated operation of the SIB units improves system dynamics and stability by mitigating initial frequency drops and tie-line power variations caused by sudden load disturbances.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.10220</dc:identifier><dc:identifier>10.11591/eei.v15i1.10220</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 11-26</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10220/4525</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>