Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Respon Ganda Elektrode Kawat Emas Terlapis Polipirol Terhadap Kation Dan Anion Dari Surfaktan Nads

Jurnal Progres Kimia Sains · Vol. 1 No. 2 (2016)

ISSN
2527-354X, 2252-5181
Terbit
2016-02-16
Penerbit
Universitas Halu Oleo
Bahasa
eng

Abstrak

The coating of gold wire electrode as working electrode with polypyrrole throughelectropolymerization by ciclyc voltammetry was performanced in the 0.01 M pyrrole solutioncontaining 1,0 ´ 10-4 M HDS dopant and 0.01 M KCl, KBr, and KI supporting electrolytes,respectively. The coated electrode prepared by KCl supporting electrolyte has the respontoward Na+ cations with highest sensitivity of 44.0 mV/decade in the concentration range of5,0 ´ 10-5 – 1,0 ´ 10-3 M and toward DS- anions with highest sensitivity of 26.2 mV/decadein the concentration range of 1,0 ´ 10-15 – 1,0 ´ 10-12 M. Coated electrode prepared by KBrsupporting electrolyte might respon toward Na+ cations with highest sensitivity of 42.4mV/decade in the concentration range of 5,0 ´ 10-4 – 1,0 ´ 10-3 M and toward DS- anionswith highest sensitivity of 35.0 mV/decade. The coated electrode prepared by KI supprotingelectrolyte has a respon toward Na+ cations with highest sensitivity of 49.2 mV/decade in theconcentration range of 5,0 ´ 10-4 – 1,0 ´ 10-3 M and toward DS- anions with highestsensitivity of 16.5 mV/decade in the concentration range of 1,0 ´ 10-15 – 1,0 ´ 10-9 M.

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/JPK/oai, pertama di-harvest 30 Okt 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Respon Ganda Elektrode Kawat Emas Terlapis Polipirol Terhadap Kation Dan Anion Dari Surfaktan Nads</dc:title>
	<dc:creator>Watoni, Abdul Haris</dc:creator>
	<dc:description xml:lang="en-US">The coating of gold wire electrode as working electrode with polypyrrole throughelectropolymerization by ciclyc voltammetry was performanced in the 0.01 M pyrrole solutioncontaining 1,0 ´ 10-4 M HDS dopant and 0.01 M KCl, KBr, and KI supporting electrolytes,respectively. The coated electrode prepared by KCl supporting electrolyte has the respontoward Na+ cations with highest sensitivity of 44.0 mV/decade in the concentration range of5,0 ´ 10-5 – 1,0 ´ 10-3 M and toward DS- anions with highest sensitivity of 26.2 mV/decadein the concentration range of 1,0 ´ 10-15 – 1,0 ´ 10-12 M. Coated electrode prepared by KBrsupporting electrolyte might respon toward Na+ cations with highest sensitivity of 42.4mV/decade in the concentration range of 5,0 ´ 10-4 – 1,0 ´ 10-3 M and toward DS- anionswith highest sensitivity of 35.0 mV/decade. The coated electrode prepared by KI supprotingelectrolyte has a respon toward Na+ cations with highest sensitivity of 49.2 mV/decade in theconcentration range of 5,0 ´ 10-4 – 1,0 ´ 10-3 M and toward DS- anions with highestsensitivity of 16.5 mV/decade in the concentration range of 1,0 ´ 10-15 – 1,0 ´ 10-9 M.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Halu Oleo</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2016-02-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.uho.ac.id/index.php/JPK/article/view/506</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Progres Kimia Sains; Vol 1, No 2 (2011): JPKS Open Access</dc:source>
	<dc:source>2527-354X</dc:source>
	<dc:source>2252-5181</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.uho.ac.id/index.php/JPK/article/view/506/338</dc:relation>
</oai_dc:dc>