Delineating 12-lead ECG for automated ST-elevation and ST depression detection using deep learning

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 1 (2026) · hlm. 845–859

DOI
10.11591/eei.v15i1.10531
ISSN
2089-3191, 2302-9285
Terbit
2026-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

ST-elevation or ST-depression are markers of an abnormal heart condition detected through an electrocardiogram (ECG) where the tracing in the ST-segment is unusually elevated above the TP-segment (baseline). Identifying the localization of the ST-segment on an ECG is difficult because even a minor change in the ST-segment can be obscured by filtering processes. The 12-lead ECG signal is a non-invasive tool in the early detection of ST-elevation based on ST- and TP-segment, with quick and accurate interpretation. This study proposes a standard 12-lead ECG delineation model using deep learning (DL). The ECG signal has been segmented to Pstart–Pend, Pend–QRSstart, QRSstart–Rpeak, Rpeak–QRSend, QRSend-Tstart, Tstart–Tend, and Tend–Pstart. The study interpreted ST-elevation or -depression using an ECG delineation approach guided by medical rules. The findings revealed that the DL model achieved an average accuracy of 99.18%, sensitivity of 92.55%,specificity of 99.55%, precision of 92.61%, and F1-score of 92.52% in limb leads. Similarly, in chest leads, the DL model attained an accuracy of 99.16%, sensitivity of 93.10%, specificity of 99.53%, precision of 93.32%, and F1-score of 93.11%. This study also validated the DL-predicted results by a cardiologist from Mohammad Hoesin Hospital, Indonesia.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 183 tautan kepenulisan bersama · 25 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sriwijaya University
  • Politeknik Negeri Sriwijaya
  • Bandung Institute of Technology
  • Lampung University
  • Universitas Islam Negeri Imam Bonjol Padang
  • University of Indonesia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Akhiar Wista ArumSriwijaya University13
Samsuryadi SamsuryadiSriwijaya University9
Dian Palupi RiniSriwijaya University8
Sutarno SutarnoSriwijaya University7
Ghita AthalinaAfiliasi tidak diketahui6
Muhammad Alpim Alfa RolisAfiliasi tidak diketahui6
Firdaus FirdausUniversitas Islam Negeri Imam Bonjol Padang6
Hadi SyaputraSriwijaya University5
Muhammad Taufik RosenoSriwijaya University5
Bhakti Yudho SupraptoSriwijaya University4
Radiyati Umi PartanSriwijaya University4
Nyayu Latifah HusniPoliteknik Negeri Sriwijaya2
Irsyadi YaniSriwijaya University2
Ade SilviaBandung Institute of Technology2
Erwin ErwinSriwijaya University2
Mardiana MardianaLampung University1
Saparudin SaparudinSriwijaya University1
Clara Fin BadillahSriwijaya University1
Junia ErlinaSriwijaya University1
Auzan LazuardiSriwijaya University1
Tresna DewiPoliteknik Negeri Sriwijaya1
Pola RismaPoliteknik Negeri Sriwijaya1
Yurni OktarinaPoliteknik Negeri Sriwijaya1
Muhammad RorizPoliteknik Negeri Sriwijaya1
Gabriel Ekoputra Hartono CahyadiSriwijaya University1
Samsuryadi SamsuryadiSriwijaya University1
M Agung AkbarUniversity of Indonesia1
Erliza YuniartiSriwijaya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Delineating 12-lead ECG for automated ST-elevation and ST depression detection using deep learning</dc:title><dc:creator>Bambang Tutuko</dc:creator><dc:creator>Annisa Darmawahyuni</dc:creator><dc:creator>Alexander Edo Tondas</dc:creator><dc:creator>Muhammad Naufal Rachmatullah</dc:creator><dc:creator>Firdaus Firdaus</dc:creator><dc:creator>Ade Iriani Sapitri</dc:creator><dc:creator>Anggun Islami</dc:creator><dc:creator>Sukemi Sukemi</dc:creator><dc:creator>Muhammad Fachrurrozi</dc:creator><dc:creator>Siti Nurmaini</dc:creator><dc:creator>Rendy Isdwanta</dc:creator><dc:creator>Jordan Marcelino</dc:creator><dc:subject>12-lead ECG</dc:subject><dc:subject>ST-segment elevation</dc:subject><dc:subject>ST-segment depression</dc:subject><dc:subject>ECG delineation</dc:subject><dc:subject>deep learning</dc:subject><dc:subject>QRS complex detection</dc:subject><dc:subject>P-wave detection</dc:subject><dc:subject>T wave detection</dc:subject><dc:subject>precordial leads</dc:subject><dc:subject>limb leads</dc:subject><dc:subject>automated ECG analysis</dc:subject><dc:description xml:lang="en">ST-elevation or ST-depression are markers of an abnormal heart condition detected through an electrocardiogram (ECG) where the tracing in the ST-segment is unusually elevated above the TP-segment (baseline). Identifying the localization of the ST-segment on an ECG is difficult because even a minor change in the ST-segment can be obscured by filtering processes. The 12-lead ECG signal is a non-invasive tool in the early detection of ST-elevation based on ST- and TP-segment, with quick and accurate interpretation. This study proposes a standard 12-lead ECG delineation model using deep learning (DL). The ECG signal has been segmented to Pstart–Pend, Pend–QRSstart, QRSstart–Rpeak, Rpeak–QRSend, QRSend-Tstart, Tstart–Tend, and Tend–Pstart. The study interpreted ST-elevation or -depression using an ECG delineation approach guided by medical rules. The findings revealed that the DL model achieved an average accuracy of 99.18%, sensitivity of 92.55%,specificity of 99.55%, precision of 92.61%, and F1-score of 92.52% in limb leads. Similarly, in chest leads, the DL model attained an accuracy of 99.16%, sensitivity of 93.10%, specificity of 99.53%, precision of 93.32%, and F1-score of 93.11%. This study also validated the DL-predicted results by a cardiologist from Mohammad Hoesin Hospital, Indonesia.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.10531</dc:identifier><dc:identifier>10.11591/eei.v15i1.10531</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 845-859</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10531/4617</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>