Abstrak

Rectifiers are included in the non-linear load category and can create resonance in a distribution network, which can be called harmonics. In a distribution network, rectifiers (non-linear loads) distort voltage and current harmonics, resulting in power losses and reduced power quality in the network. Harmonics in the distribution power grid cannot be eliminated, but can be reduced to values that can still be tolerated and evaluated until they are by the IEEE 519-2014 Standard. This research discusses reducing harmonic values in distribution networks designed in a simulation to implement a combination (hybrid) of series active and passive filters of the high pass and high pass type-C types. The results of research using the installation of high pass filters, type C filters, series active filters, hybrid-1 filters, and hybrid-2 filters, respectively, for each current total harmonic distortion (THD) value are 15.93%, 16.15%, 8.51%, 0.27%, and 0.25% where the current THD value when using the two hybrid filters is below the specified standard limit, namely 5%. By installing a hybrid filter, the harmonic value in each feeder is much better than installing a single series active filter, a high pass filter, and a type-C filter.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 85 tautan kepenulisan bersama · 43 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Sumatera Utara
  • Universitas Negeri Padang
  • Institut Teknologi Sepuluh Nopember
  • Universiti Teknologi MARA
  • King Mongkut's Institute of Technology Ladkrabang
  • Kanazawa University
  • University of Technology Malaysia
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Naemah MubarakahUniversitas Sumatera Utara2
Soeharwinto SoeharwintoUniversitas Sumatera Utara2
Issarachai NgamrooKing Mongkut's Institute of Technology Ladkrabang2
Farel SitumeangUniversitas Sumatera Utara2
Syahrun MubarokUniversitas Sumatera Utara2
Naomi AzhariUniversitas Sumatera Utara2
Wahyu Franciscus SihotangUniversitas Sumatera Utara2
Mohd Najib Mohd HussainUniversiti Teknologi MARA2
Faizzufar TaqyUniversitas Sumatera Utara2
Hafizh PrihtiadiState University of Malang2
Timothy Juan Hartanto LumbanrajaUniversitas Sumatera Utara1
Yasunori TanakaKanazawa University1
Yanuar Zulardiansyah AriefUniversity of Technology Malaysia1
Maulaya MuhammadUniversitas Sumatera Utara1
Riswan DinziUniversitas Sumatera Utara1
Mai Kai Suan TialYangon Technological University1
Azrial Aziz Azhari NasutionUniversitas Sumatera Utara1
Muhammad Aulia DeskyMalikussaleh University1
Maksum PinemUniversitas Sumatera Utara1
Christian Kevin Imanuel SimarmataUniversitas Sumatera Utara1
Ahyanuardi AhyanuardiUniversitas Negeri Padang1
Aswardi AswardiUniversitas Negeri Padang1
Moh. JauhariPoliteknik Negeri Madura1
Mochamad AshariInstitut Teknologi Sepuluh Nopember1
Adel A. ElbasetMinia University1
Heri SuryoatmojoInstitut Teknologi Sepuluh Nopember1
Alwy Muhammad RaviTelkom University1
Tomi Saputra Jaya TambunUniversitas Sumatera Utara1
Sihar Parlinggoman PanjaitanUniversitas Sumatera Utara1
Kasmir TanjungUniversitas Sumatera Utara1
Syiska YanaUniversitas Sumatera Utara1
Mukhlidi MuskhirUniversitas Negeri Padang1
Taali TaaliUniversitas Negeri Padang1
Agus Kivander SaragiUniversitas Sumatera Utara1
M. A. AkbarUniversitas Sumatera Utara1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design and analysis of hybrid filters for harmonic reduction in three-phase nonlinear rectifier loads</dc:title><dc:creator>Yulianta Siregar</dc:creator><dc:creator>Daniel Julian Sinaga</dc:creator><dc:creator>Nur Nabila Mohamed</dc:creator><dc:creator>Dedet Candra Riawan</dc:creator><dc:creator>Muldi Yuhendri</dc:creator><dc:subject>harmonic compensation</dc:subject><dc:subject>hybrid filter</dc:subject><dc:subject>series active power filter</dc:subject><dc:subject>passive filters</dc:subject><dc:subject>high-pass filter</dc:subject><dc:subject>three-phase rectifier</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>power quality</dc:subject><dc:subject>IEEE 519-2014</dc:subject><dc:description xml:lang="en">Rectifiers are included in the non-linear load category and can create resonance in a distribution network, which can be called harmonics. In a distribution network, rectifiers (non-linear loads) distort voltage and current harmonics, resulting in power losses and reduced power quality in the network. Harmonics in the distribution power grid cannot be eliminated, but can be reduced to values that can still be tolerated and evaluated until they are by the IEEE 519-2014 Standard. This research discusses reducing harmonic values in distribution networks designed in a simulation to implement a combination (hybrid) of series active and passive filters of the high pass and high pass type-C types. The results of research using the installation of high pass filters, type C filters, series active filters, hybrid-1 filters, and hybrid-2 filters, respectively, for each current total harmonic distortion (THD) value are 15.93%, 16.15%, 8.51%, 0.27%, and 0.25% where the current THD value when using the two hybrid filters is below the specified standard limit, namely 5%. By installing a hybrid filter, the harmonic value in each feeder is much better than installing a single series active filter, a high pass filter, and a type-C filter.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.10971</dc:identifier><dc:identifier>10.11591/eei.v15i1.10971</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 71-86</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10971/4530</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>