Abstrak

The growing need to supply quality electrical energy to end-users has given rise to various studies and research on the technical parameters that this energy should possess. In addition, many users perceive that many of the problems in the operation of their household appliances are related to the quality of the electrical energy that reaches their homes. One of the fundamental problems affecting the quality of electrical power is the so called voltage dips, which are nothing more than disturbances of great relevance due to their direct consequences, secondary effects, and frequency of occurrence. In this research, a study is conducted to evaluate the occurrence of three-phase voltage dips in a simplified electrical network in Santiago de Cuba, Cuba. As a result, the Santiago Norte substation presents the most detrimental behavior. In addition, 50% of the simulations performed on the behavior of the Santiago East Substation, which handles a voltage of 13.8 kV, showed that it is the substation where the deepest voltage dips occur. Based on the results obtained, it has been decided to change the transformer tapping of the affected substations to reduce the occurrence of voltage dips and ensure stable operation in the event of three phase faults in the power system under analysis.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 107 tautan kepenulisan bersama · 53 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad de la Costa
  • Universidad Técnica de Manabí
  • Universidad de Oriente
  • Universidad del Magdalena
  • Universidade Federal Rural de Pernambuco
  • Universidad Simón Bolívar
  • Universidad de Las Tunas
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
María Rodríguez GámezUniversidad Técnica de Manabí4
Antonio Vázquez PérezUniversidad Técnica de Manabí4
Eliana Noriega AngaritaUniversidad de la Costa3
Yelena Pérez ZamoraUniversidad de Oriente2
Israel Francisco Benítez PinaUniversidad de Oriente2
Reinel Beltrán AguedoUniversidade Federal Rural de Pernambuco2
Ania Lussón CervantesUniversidade Federal Rural de Pernambuco2
Angel R. RicardoAfiliasi tidak diketahui1
Guillermo González-YeroAfiliasi tidak diketahui1
Mirelys Torres PérezUniversidad de Las Tunas1
Christian Manuel Moreno RochaUniversidad de la Costa1
Celene Milanés BatistaUniversidad de la Costa1
Willian Fernando Arguello RodríguezUniversidad de la Costa1
Arley Jesús Fontalvo BallesterosUniversidad de la Costa1
Genial Belvine Epeni TomboUniversidad Técnica de Manabí1
Guillermo Antonio Loor CastilloUniversidad Técnica de Manabí1
Etna Mercedes Bayona VelásquezUniversidad del Magdalena1
Ana Pirela-RíosUniversidad EAFIT1
Ever Marín-GiraldoUniversidad del Magdalena1
Frank Grau-MerconchinAfiliasi tidak diketahui1
Orestes Nicolás Hernández AreuPolytechnic José Antonio Echeverría1
Michael Montenegro-RomeroUniversidad de la Costa1
Oscar Quintero-OspinoUniversidad de la Costa1
Rogger José Andrade CedeñoUniversidad Central de Venezuela1
Jesús Pérez‐RodríguezUniversidad Técnica de Manabí1
Carlos David Amaya-JaramilloUniversidad Técnica Estatal de Quevedo1
Ciaddy Gina Rodríguez-BorgesUniversidad Técnica de Manabí1
Endrickson Ramón Vera- CedenoUniversidad Laica Eloy Alfaro de Manabí1
Luis Santiago Quiroz-FernándezUniversidad Técnica de Manabí1
Raidel Fidel Linares VicenteUniversidad de Oriente1
Rodrigo Isacc Fonnegra RodríguezUniversidad de la Costa1
José Javier Lozano MendozaUniversidad de la Costa1
Jairo Mora MartínezAfiliasi tidak diketahui1
Michelle Hernandez CrespoUniversidad de la Costa1
Paulo José Fruto PertuzUniversidad de la Costa1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Three-phase voltage dips in load nodes of the electrical network of the Santiago de Cuba province measure for its correction</dc:title><dc:creator>José Ricardo Núñez Álvarez</dc:creator><dc:creator>Janette Cervantes Oliva</dc:creator><dc:creator>Ramón Antonio Zambrano-Mero</dc:creator><dc:creator>Hernan Hernández-Herrera</dc:creator><dc:creator>Yolanda Llosas Albuerne</dc:creator><dc:subject>power quality</dc:subject><dc:subject>electrical networks</dc:subject><dc:subject>load nodes</dc:subject><dc:subject>substations</dc:subject><dc:subject>transformer tap adjustment</dc:subject><dc:subject>three-phase fault</dc:subject><dc:subject>Santiago de Cuba</dc:subject><dc:description xml:lang="en">The growing need to supply quality electrical energy to end-users has given rise to various studies and research on the technical parameters that this energy should possess. In addition, many users perceive that many of the problems in the operation of their household appliances are related to the quality of the electrical energy that reaches their homes. One of the fundamental problems affecting the quality of electrical power is the so called voltage dips, which are nothing more than disturbances of great relevance due to their direct consequences, secondary effects, and frequency of occurrence. In this research, a study is conducted to evaluate the occurrence of three-phase voltage dips in a simplified electrical network in Santiago de Cuba, Cuba. As a result, the Santiago Norte substation presents the most detrimental behavior. In addition, 50% of the simulations performed on the behavior of the Santiago East Substation, which handles a voltage of 13.8 kV, showed that it is the substation where the deepest voltage dips occur. Based on the results obtained, it has been decided to change the transformer tapping of the affected substations to reduce the occurrence of voltage dips and ensure stable operation in the event of three phase faults in the power system under analysis.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.10172</dc:identifier><dc:identifier>10.11591/eei.v15i1.10172</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 27-38</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10172/4526</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>