Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Dual-domain analysis of CGM data for personalized metabolic health management

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 2 (2026) · hlm. 1391–1402

DOI
10.11591/eei.v15i2.10702
ISSN
2089-3191, 2302-9285
Terbit
2026-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Time-domain metrics on a continuous glucose monitoring (CGM) miss hidden dynamics, but frequency-domain features detect up on oscillating patterns, which makes it easier to measure glucose variability and gain clinical understanding. This study aimed to analyze the time and frequency domain features of CGM data for three patients (PtID 65, PtID 109, and PtID 134) to assess glucose variability and control. CGM data were collected over a specified period, with key metrics such as mean glucose, standard deviation (SD), time in range (TIR), and spectral features being computed. The analysis included both time domain and frequency domain features. PtID 109 exhibited the highest mean glucose (207.86 mg/dL) and greatest variability, reflected in the highest SD (85.57 mg/dL) and the lowest TIR (38.24%). PtID 134 showed the most stable glucose levels with the highest TIR (73.60%) and the lowest SD (59.81 mg/dL). Frequency domain analysis revealed that PtID:134 had the highest spectral flatness, indicating more variability in the glucose signal’s frequency content. PtID 109 had the lowest TIR at 38.24%, whereas PtID 134 achieved 73.60%, indicating a 24% enhancement and demonstrating superior glucose stability. Dual-domain analysis offers thorough framework for comprehending glucose variability, facilitating individualized treatment and enhanced metabolic health care.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sri Sairam Engineering College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Dual-domain analysis of CGM data for personalized metabolic health management</dc:title><dc:creator>Selvaraj Gowriswari</dc:creator><dc:creator>S. Brindha</dc:creator><dc:subject>continuous glucose monitoring</dc:subject><dc:subject>glycemic variability</dc:subject><dc:subject>frequency domain analysis</dc:subject><dc:subject>time-domain features</dc:subject><dc:subject>spectral flatness</dc:subject><dc:subject>time in range</dc:subject><dc:subject>glycemic control</dc:subject><dc:description xml:lang="en">Time-domain metrics on a continuous glucose monitoring (CGM) miss hidden dynamics, but frequency-domain features detect up on oscillating patterns, which makes it easier to measure glucose variability and gain clinical understanding. This study aimed to analyze the time and frequency domain features of CGM data for three patients (PtID 65, PtID 109, and PtID 134) to assess glucose variability and control. CGM data were collected over a specified period, with key metrics such as mean glucose, standard deviation (SD), time in range (TIR), and spectral features being computed. The analysis included both time domain and frequency domain features. PtID 109 exhibited the highest mean glucose (207.86 mg/dL) and greatest variability, reflected in the highest SD (85.57 mg/dL) and the lowest TIR (38.24%). PtID 134 showed the most stable glucose levels with the highest TIR (73.60%) and the lowest SD (59.81 mg/dL). Frequency domain analysis revealed that PtID:134 had the highest spectral flatness, indicating more variability in the glucose signal’s frequency content. PtID 109 had the lowest TIR at 38.24%, whereas PtID 134 achieved 73.60%, indicating a 24% enhancement and demonstrating superior glucose stability. Dual-domain analysis offers thorough framework for comprehending glucose variability, facilitating individualized treatment and enhanced metabolic health care.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i2.10702</dc:identifier><dc:identifier>10.11591/eei.v15i2.10702</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 2 (2026); 1391-1402</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10702/4662</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>