Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Electrocardiogram signal denoising and heart disease classification

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 3 (2026) · hlm. 2116–2125

DOI
10.11591/eei.v15i3.11276
ISSN
2089-3191, 2302-9285
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Electrocardiogram (ECG) recordings are often contaminated by baseline wander (BLW), power-line interference, and motion or muscular noise, reducing the reliability of both manual and automated diagnosis. The paper presents a light and reproducible MATLAB pipeline applying finite-impulse-response (FIR) filters designed using Kaiser and Hamming windows for ECG denoising, which after R-peak detection follows an RR-interval analysis for classification of heart rate as tachycardia, bradycardia, or normal. In the experiments, 15 MIT-BIH records with added Gaussian noise at several SNR levels were used for benchmarking the performance of denoising. FIR band-pass and low-pass windowed filters improved the clarity of the waveform and supported robust R-peak detection; RR-interval-based classification reached a mean accuracy of ~98.7% on the study set. The approach is computationally lightweight and quite suitable for embedded real-time deployment but is restricted to the small sample of records and synthetic noise modeling. Future work will compare the efficacy of windowed FIR filtering against modern deep-learning denoisers (CNN/RNN/GAN architectures) and assess the pipeline in larger clinical datasets.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 22 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Mohan Babu University
  • Applied Science Private University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ch. AmarendraKoneru Lakshmaiah Education Foundation1
K. Harinadha ReddyKoneru Lakshmaiah Education Foundation1
Ch. Rami ReddyApplied Science Private University1
B. V. RajannaRajannaAfiliasi tidak diketahui1
Sk. MoulaliKoneru Lakshmaiah Education Foundation1
G. VenkateswarluAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Electrocardiogram signal denoising and heart disease classification</dc:title><dc:creator>K. Venkata Siva Reddy</dc:creator><dc:creator>M Balaji</dc:creator><dc:subject>ECG denoising</dc:subject><dc:subject>heart disease classification</dc:subject><dc:subject>baseline wander</dc:subject><dc:subject>power line interference</dc:subject><dc:subject>motion artifacts</dc:subject><dc:subject>FIR filters</dc:subject><dc:subject>Kaiser window</dc:subject><dc:subject>Hamming window</dc:subject><dc:subject>R-peak detection</dc:subject><dc:subject>RR interval analysis</dc:subject><dc:subject>tachycardia</dc:subject><dc:subject>bradycardia</dc:subject><dc:subject>MIT-BIH arrhythmia database</dc:subject><dc:subject>Gaussian noise</dc:subject><dc:description xml:lang="en">Electrocardiogram (ECG) recordings are often contaminated by baseline wander (BLW), power-line interference, and motion or muscular noise, reducing the reliability of both manual and automated diagnosis. The paper presents a light and reproducible MATLAB pipeline applying finite-impulse-response (FIR) filters designed using Kaiser and Hamming windows for ECG denoising, which after R-peak detection follows an RR-interval analysis for classification of heart rate as tachycardia, bradycardia, or normal. In the experiments, 15 MIT-BIH records with added Gaussian noise at several SNR levels were used for benchmarking the performance of denoising. FIR band-pass and low-pass windowed filters improved the clarity of the waveform and supported robust R-peak detection; RR-interval-based classification reached a mean accuracy of ~98.7% on the study set. The approach is computationally lightweight and quite suitable for embedded real-time deployment but is restricted to the small sample of records and synthetic noise modeling. Future work will compare the efficacy of windowed FIR filtering against modern deep-learning denoisers (CNN/RNN/GAN architectures) and assess the pipeline in larger clinical datasets.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i3.11276</dc:identifier><dc:identifier>10.11591/eei.v15i3.11276</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 3 (2026); 2116-2125</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11276/4825</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>