Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

FA-optimized fractional order PI control for bidirectional V2G and G2V systems with integrated subsystem management

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 3 (2026) · hlm. 2064–2077

DOI
10.11591/eei.v15i3.10895
ISSN
2089-3191, 2302-9285
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper presents a Firefly algorithm (FA)-optimized, fractional order proportional-integral (FOPI), control strategy for bidirectional vehicle-togrid (V2G), and grid-to-vehicle (G2V) systems. The optimization focuses on minimizing key performance indices—integral of time-weighted absolute error (ITAE), integral of squared error (ISE), and integral of absolute error (IAE)—to achieve optimal dynamic response and energy efficiency. The control system incorporates converter with battery controller. The FA is employed to fine-tune the FOPI parameters, leveraging its robust global search capability to balance trade-offs between fast response, minimal overshoot, and stability. Simulation results validate the effectiveness of the proposed approach, demonstrating superior performance compared to conventional proportional–integral (PI) controllers, with ITAE reduced by 63.4% compared to PI controller. This study provides a scalable and efficient solution for advanced energy management in V2G/G2V systems, contributing to the sustainable integration of electric vehicles (EVs) with smart grids.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • B.S. Abdur Rahman Crescent Institute of Science & Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">FA-optimized fractional order PI control for bidirectional V2G and G2V systems with integrated subsystem management</dc:title><dc:creator>Mohamed Shiek Mothi</dc:creator><dc:creator>M. Mohamed Ismail</dc:creator><dc:subject>fractional order PI control</dc:subject><dc:subject>firefly algorithm</dc:subject><dc:subject>vehicle-to-grid</dc:subject><dc:subject>grid-to-vehicle</dc:subject><dc:subject>bidirectional power flow</dc:subject><dc:subject>electric vehicle energy management</dc:subject><dc:subject>battery controller</dc:subject><dc:subject>converter control</dc:subject><dc:subject>controller tuning</dc:subject><dc:subject>ITAE</dc:subject><dc:subject>IAE</dc:subject><dc:subject>Ise</dc:subject><dc:subject>smart grid integration</dc:subject><dc:description xml:lang="en">This paper presents a Firefly algorithm (FA)-optimized, fractional order proportional-integral (FOPI), control strategy for bidirectional vehicle-togrid (V2G), and grid-to-vehicle (G2V) systems. The optimization focuses on minimizing key performance indices—integral of time-weighted absolute error (ITAE), integral of squared error (ISE), and integral of absolute error (IAE)—to achieve optimal dynamic response and energy efficiency. The control system incorporates converter with battery controller. The FA is employed to fine-tune the FOPI parameters, leveraging its robust global search capability to balance trade-offs between fast response, minimal overshoot, and stability. Simulation results validate the effectiveness of the proposed approach, demonstrating superior performance compared to conventional proportional–integral (PI) controllers, with ITAE reduced by 63.4% compared to PI controller. This study provides a scalable and efficient solution for advanced energy management in V2G/G2V systems, contributing to the sustainable integration of electric vehicles (EVs) with smart grids.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i3.10895</dc:identifier><dc:identifier>10.11591/eei.v15i3.10895</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 3 (2026); 2064-2077</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10895/4758</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>