Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 3 (2026) · hlm. 1984–2002

DOI
10.11591/eei.v15i3.10719
ISSN
2089-3191, 2302-9285
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The integration of solar and wind energy has increased electricity generation but also introduced power quality disturbances (PQDs) that threaten grid stability. This study examines the detection and classification of five PQD types—voltage sag, swell, interruption, harmonics, and normal conditions—across noisy environments (0, 10, 20, and 30 dB) signal-to-noise ratio (SNR). Traditional methods— support vector machine (SVM), random forest (RF), artificial neural networks (ANN), and 1D convolutional neural networks (1D CNN)—are evaluated on raw signal data, while advanced models—2D CNN and fused 2D CNN-LSTM—utilize time-frequency representations (continuous wavelet transform (CWT) and short-time Fourier transform (STFT)). Results show that deep learning (DL) models achieve high accuracy even in noisy environments, with the fused 2D CNNLSTM using CWT outperforming all other methods. Noise adversely affects feature extraction, with CWT consistently outperforming STFT under low SNR conditions. These findings demonstrate that combining DL models with robust time-frequency analysis and temporal modeling enhances PQD classification and supports dependable monitoring in smart grid environments.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Boumerdes
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Afaf SaoudUniversity of Boumerdes1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification</dc:title><dc:creator>Bouchra Feriel KHALDI</dc:creator><dc:creator>Fatma Zohra Dekhandji</dc:creator><dc:creator>Abdelmadjid Recioui</dc:creator><dc:subject>power quality disturbance classification</dc:subject><dc:subject>voltage sag</dc:subject><dc:subject>voltage swell</dc:subject><dc:subject>voltage interruption</dc:subject><dc:subject>harmonic distortion</dc:subject><dc:subject>continuous wavelet transform</dc:subject><dc:subject>short-time Fourier transform</dc:subject><dc:subject>2D convolutional neural network</dc:subject><dc:subject>CNN-LSTM hybrid model</dc:subject><dc:subject>time-frequency representation</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:subject>noise robustness</dc:subject><dc:subject>renewable energy integration</dc:subject><dc:subject>smart grid monitoring</dc:subject><dc:description xml:lang="en">The integration of solar and wind energy has increased electricity generation but also introduced power quality disturbances (PQDs) that threaten grid stability. This study examines the detection and classification of five PQD types—voltage sag, swell, interruption, harmonics, and normal conditions—across noisy environments (0, 10, 20, and 30 dB) signal-to-noise ratio (SNR). Traditional methods— support vector machine (SVM), random forest (RF), artificial neural networks (ANN), and 1D convolutional neural networks (1D CNN)—are evaluated on raw signal data, while advanced models—2D CNN and fused 2D CNN-LSTM—utilize time-frequency representations (continuous wavelet transform (CWT) and short-time Fourier transform (STFT)). Results show that deep learning (DL) models achieve high accuracy even in noisy environments, with the fused 2D CNNLSTM using CWT outperforming all other methods. Noise adversely affects feature extraction, with CWT consistently outperforming STFT under low SNR conditions. These findings demonstrate that combining DL models with robust time-frequency analysis and temporal modeling enhances PQD classification and supports dependable monitoring in smart grid environments.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i3.10719</dc:identifier><dc:identifier>10.11591/eei.v15i3.10719</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 3 (2026); 1984-2002</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10719/4752</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>