Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Robust stall detection of three-phase induction motors using transient-aware current-speed monitoring

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 4 (2026) · hlm. 3009–3021

DOI
10.11591/eei.v15i4.13216
ISSN
2089-3191, 2302-9285
Terbit
2026-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Reliable stall detection is essential for protecting three-phase induction motors from thermal damage while maintaining uninterrupted industrial operation. Conventional threshold-based protection methods often struggle to distinguish transient overload events from sustained stall conditions, resulting in nuisance trips or delayed fault detection under dynamic operating conditions. This paper proposes a robust transient-aware stall detection framework that combines stator current monitoring, rotor speed monitoring, startup inhibition, adaptive activation logic, and hold-time verification within a lightweight threshold-based decision process. The proposed algorithm was implemented and evaluated using a MATLAB/Simulink model of a three-phase squirrel-cage induction motor under representative operating scenarios, including motor startup, temporary overload, and sustained stall conditions. Simulation results demonstrate that the proposed framework successfully suppresses unnecessary trips during short-duration overloads by allowing the motor to re-accelerate after transient disturbances. Conversely, when abnormal operating conditions persist beyond the predefined hold time, the algorithm reliably identifies an actual stall and activates the protection relay to disconnect the motor. By integrating temporal verification with simultaneous current and speed monitoring, the proposed framework effectively discriminates recoverable transient events from sustained stall conditions while maintaining low computational complexity. These characteristics make the proposed method suitable for practical real-time induction motor protection in industrial automation applications.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 112 tautan kepenulisan bersama · 62 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Universitas Ahmad Dahlan
  • Diponegoro University
  • Universiti Malaysia Perlis
  • Yogyakarta State University
  • Tun Hussein Onn University of Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Auzani JidinUniversiti Teknikal Malaysia Melaka40
Nik Rumzi Nik IdrisUniversity of Technology Malaysia31
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka28
Awang JusohUniversity of Technology Malaysia21
Mustafa ManapUniversiti Teknikal Malaysia Melaka17
Mohammad JannatiUniversity of Technology Malaysia16
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia16
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka13
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka13
Shahreen binti KasimTun Hussein Onn University of Malaysia11
Mohamed SalemUniversiti Sains Malaysia11
Ibrahim AlhamrouniUniversity of Kuala Lumpur10
Lina HandayaniUniversitas Ahmad Dahlan9
Mahmoud ZadehbagheriIslamic Azad University Yasuj9
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka7
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka7
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka7
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka7
Shahrin Md AyobUniversity of Technology Malaysia7
Hendril Satrian PurnamaAfiliasi tidak diketahui6
Watra ArsadiandoAfiliasi tidak diketahui6
Mochammad FactaDiponegoro University6
Mohammad Faridun Naim TajuddinUniversiti Malaysia Perlis6
Munawar Agus RiyadiDiponegoro University5
Deris StiawanSriwijaya University5
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka5
Ahmed Hussein AliIraqi University5
Tri WahonoUniversitas Ahmad Dahlan5
Azralmukmin AzmiUniversiti Malaysia Perlis5
Norjulia Mohamad NordinUniversity of Technology Malaysia5
Mostafa Abdulghafoor MohammedAl-Imam Al-Adham University College5
Imam Much Ibnu SubrotoSultan Agung Islamic University4
Muhammad AdoUniversity of Technology Malaysia4
Mehdi DadkhahIslamic Azad University, Tehran4
Mohd Arfian IsmailUniversiti Malaysia Pahang Al-Sultan Abdullah4
Anggit PamungkasAfiliasi tidak diketahui4

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Robust stall detection of three-phase induction motors using transient-aware current-speed monitoring</dc:title><dc:creator>Muchlas Muchlas</dc:creator><dc:creator>Herman Dwi Surjono</dc:creator><dc:creator>Tole Sutikno</dc:creator><dc:creator>Barry Nur Setyanto</dc:creator><dc:subject>stall detection</dc:subject><dc:subject>three-phase induction motor</dc:subject><dc:subject>squirrel cage induction motor</dc:subject><dc:subject>motor protection</dc:subject><dc:subject>protective relays</dc:subject><dc:subject>thermal damage prevention</dc:subject><dc:description xml:lang="en">Reliable stall detection is essential for protecting three-phase induction motors from thermal damage while maintaining uninterrupted industrial operation. Conventional threshold-based protection methods often struggle to distinguish transient overload events from sustained stall conditions, resulting in nuisance trips or delayed fault detection under dynamic operating conditions. This paper proposes a robust transient-aware stall detection framework that combines stator current monitoring, rotor speed monitoring, startup inhibition, adaptive activation logic, and hold-time verification within a lightweight threshold-based decision process. The proposed algorithm was implemented and evaluated using a MATLAB/Simulink model of a three-phase squirrel-cage induction motor under representative operating scenarios, including motor startup, temporary overload, and sustained stall conditions. Simulation results demonstrate that the proposed framework successfully suppresses unnecessary trips during short-duration overloads by allowing the motor to re-accelerate after transient disturbances. Conversely, when abnormal operating conditions persist beyond the predefined hold time, the algorithm reliably identifies an actual stall and activates the protection relay to disconnect the motor. By integrating temporal verification with simultaneous current and speed monitoring, the proposed framework effectively discriminates recoverable transient events from sustained stall conditions while maintaining low computational complexity. These characteristics make the proposed method suitable for practical real-time induction motor protection in industrial automation applications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i4.13216</dc:identifier><dc:identifier>10.11591/eei.v15i4.13216</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 4 (2026); 3009-3021</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/13216/4870</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>