Sensitivity analysis of voltage limit in radial AC microgrids considering the loading condition and line length

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 3843–3851

DOI
10.11591/eei.v15i5.11620
ISSN
2089-3191, 2302-9285
Terbit
2026-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

A sensitivity analysis of voltage compliance in radial AC microgrids linked to a low-voltage main grid is presented in this paper, with an emphasis on the combined effects of feeder length and load-generation balance. Three loading scenarios: demand exceeding generation, demand matching generation, and generation exceeding demand are used to apply a Newton-Raphson power flow algorithm to a radial network with five distributed generators (DGs) and five loads. Feeder lengths, both long and short, are assessed for every condition. The findings indicate that voltage falls below the IEEE 1547 lower limit of 207 V when demand exceeds generation with long feeders (200 m line sections), falling as low as 166.9 V at the farthest load, potentially causing load shedding and DG disconnection. On the other hand, even in extended feeder situations, voltages stay within the acceptable ±10% range when generation matches or surpasses demand. These results offer useful recommendations for feeder design and DG placement in grid-connected microgrids, as well as quantitative insights into worst-case operation scenarios.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 24 tautan kepenulisan bersama · 22 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Princess Sumaya University for Technology
  • Tafila Technical University
  • Philadelphia University
  • Jordan University of Science and Technology
  • Jouf University
  • University of Akron
  • Université du Québec
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Salman HarasisTafila Technical University2
Khaled AlzaareerPhiladelphia University2
Saher AlbatranJordan University of Science and Technology1
Eyad K. AlmaitaTafila Technical University1
Mamdouh L. AlghaythiJouf University1
Mohammad Arifur RahmanUniversity of Akron1
Khaled AlzaareeUniversité du Québec1
Jian XieUniversität Ulm1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Sensitivity analysis of voltage limit in radial AC microgrids considering the loading condition and line length</dc:title><dc:creator>Qusay Salem</dc:creator><dc:creator>Rafat Aljarrah</dc:creator><dc:subject>voltage compliance</dc:subject><dc:subject>voltage constraints</dc:subject><dc:subject>feeder length</dc:subject><dc:subject>generation-load balance</dc:subject><dc:subject>distributed generation</dc:subject><dc:subject>load shedding</dc:subject><dc:subject>distributed generation placement</dc:subject><dc:subject>feeder design</dc:subject><dc:subject>IEEE 1547</dc:subject><dc:subject>low-voltage grid connection</dc:subject><dc:subject>sensitivity analysis</dc:subject><dc:description xml:lang="en">A sensitivity analysis of voltage compliance in radial AC microgrids linked to a low-voltage main grid is presented in this paper, with an emphasis on the combined effects of feeder length and load-generation balance. Three loading scenarios: demand exceeding generation, demand matching generation, and generation exceeding demand are used to apply a Newton-Raphson power flow algorithm to a radial network with five distributed generators (DGs) and five loads. Feeder lengths, both long and short, are assessed for every condition. The findings indicate that voltage falls below the IEEE 1547 lower limit of 207 V when demand exceeds generation with long feeders (200 m line sections), falling as low as 166.9 V at the farthest load, potentially causing load shedding and DG disconnection. On the other hand, even in extended feeder situations, voltages stay within the acceptable ±10% range when generation matches or surpasses demand. These results offer useful recommendations for feeder design and DG placement in grid-connected microgrids, as well as quantitative insights into worst-case operation scenarios.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.11620</dc:identifier><dc:identifier>10.11591/eei.v15i5.11620</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 3843-3851</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11620/4970</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>