Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Electrocardiogram signal modeling based on regular-pulse excitation

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 4107–4119

DOI
10.11591/eei.v15i5.11464
ISSN
2089-3191, 2302-9285
Terbit
2026-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The growing demand for modern wearable sensors and internet of things (IoT) telemedicine systems requires lightweight data compression methods aimed at reducing transmission bandwidth and wireless power consumption while maintaining high clinical diagnostic quality. Traditional methods usually demand complex processing or distort electrocardiogram (ECG) waveform characteristics, especially when high compression ratios (CRs) are targeted. This paper presents an efficient, lightweight ECG compression framework combining predictive coding with N-residual sparse sampling, which retains only one residual sample for every N data points. By integrating linear predictive coding (LPC), sparse residual sampling, and streamlined quantization and encoding, the proposed approach eliminates the need for computationally heavy transformations, prior model training, or predefined codebooks. Experimental evaluations demonstrate perfect reconstruction of the ECG signal at CRs up to 4. Optimal subsampling achieves CRs between 14.6 and 28.4, with signal-to-noise ratio (SNR) values ranging from 15.73 dB to 42.5 dB and percent root-mean-square difference (PRD) between 1.9% and 5.6%, while consistently keeping PRD below 9%. With its minimal computational overhead, low memory footprint, and preserved diagnostic integrity, this method is well-suited for energy-efficient, real-time implementation on resource-constrained wearable healthcare devices.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 50 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • American University of the Middle East
  • German Jordanian University
  • Hashemite University
  • Yarmouk University
  • Lebanese German University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Samer J. AlabedGerman Jordanian University6
Nour MostafaAmerican University of the Middle East2
Amer AlsarairaGerman Jordanian University2
Issam MaazAmerican University of the Middle East1
Wael Hosny Fouad AlyAmerican University of the Middle East1
Chamseddine ZakiAmerican University of the Middle East1
Omar A. SaraerehHashemite University1
Ahmed Younes ShdefatAmerican University of the Middle East1
Zakwan Al-ArnaoutAmerican University of the Middle East1
Bahaa Al-SheikhYarmouk University1
Lama Bou FarahLebanese German University1
Sameer Ahmad HasanGerman Jordanian University1
Yasin OmarGerman Jordanian University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Electrocardiogram signal modeling based on regular-pulse excitation</dc:title><dc:creator>Samer Alabed</dc:creator><dc:creator>Mohammad Al-Rabayah</dc:creator><dc:creator>Omar M. Bwaliez</dc:creator><dc:subject>ECG signal compression</dc:subject><dc:subject>ECG signal modeling</dc:subject><dc:subject>linear predictive coding</dc:subject><dc:subject>predictive coding</dc:subject><dc:subject>wearable sensors</dc:subject><dc:subject>telemedicine</dc:subject><dc:subject>energy-efficient signal processing</dc:subject><dc:subject>resource-constrained devices</dc:subject><dc:subject>high compression ratio</dc:subject><dc:description xml:lang="en">The growing demand for modern wearable sensors and internet of things (IoT) telemedicine systems requires lightweight data compression methods aimed at reducing transmission bandwidth and wireless power consumption while maintaining high clinical diagnostic quality. Traditional methods usually demand complex processing or distort electrocardiogram (ECG) waveform characteristics, especially when high compression ratios (CRs) are targeted. This paper presents an efficient, lightweight ECG compression framework combining predictive coding with N-residual sparse sampling, which retains only one residual sample for every N data points. By integrating linear predictive coding (LPC), sparse residual sampling, and streamlined quantization and encoding, the proposed approach eliminates the need for computationally heavy transformations, prior model training, or predefined codebooks. Experimental evaluations demonstrate perfect reconstruction of the ECG signal at CRs up to 4. Optimal subsampling achieves CRs between 14.6 and 28.4, with signal-to-noise ratio (SNR) values ranging from 15.73 dB to 42.5 dB and percent root-mean-square difference (PRD) between 1.9% and 5.6%, while consistently keeping PRD below 9%. With its minimal computational overhead, low memory footprint, and preserved diagnostic integrity, this method is well-suited for energy-efficient, real-time implementation on resource-constrained wearable healthcare devices.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.11464</dc:identifier><dc:identifier>10.11591/eei.v15i5.11464</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 4107-4119</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11464/4991</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>