Akses terbuka
Jurnal
SINTA 1
Finite-set MPC for a 7-level cascaded H-bridge simulation-based evaluation with reference extrapolation and non-idealities
Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 3895–3907
ISSN 2089-3191, 2302-9285
Terbit 2026-10-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Multilevel cascaded H-bridge (CHB) inverters are widely used in power conversion systems because they can create high-quality voltage waveforms with low harmonic distortion. However, the predictive control of multilevel converters faces challenges such as computational delays, switching dynamics, and maintaining performance under nonideal conditions. This study explores finite-control-set model predictive control for a three-phase seven-level CHB inverter with an inductor capacitor inductor (LCL) filter, taking into account hardware-related imperfections. A discrete state-space model and a voltage-tracking cost function are used to assess 343 possible switching vectors at each sampling interval. Second-order reference extrapolation is applied to manage the typical one-sample actuation delay in real-time digital systems. Simulation results show that, in ideal conditions, the inverter achieves a voltage total harmonic distortion (THD) of less than 0.1% and a power factor close to one. Under realistic disturbances, such as dc-link voltage drops and load imbalances, the system remained stable, with the THD increasing slightly to approximately 5%. Thus, the controller maintains good waveform quality and dynamic stability despite common disturbances in converter operations and digital control limits. The main contribution is integrating second-order reference extrapolation within a hardware-aware finite-control-set model predictive control (FCS-MPC) framework, providing a practical basis for future real-time implementation and validation through processor-in-the-loop (PIL) or hardware-in-the-loop testing.
Jaringan kolaborasi para penulis
13 penulis ·
32 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Siliwangi University Udayana University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Finite-set MPC for a 7-level cascaded H-bridge simulation-based evaluation with reference extrapolation and non-idealities</dc:title><dc:creator>Asep Andang</dc:creator><dc:creator>Muhammad Aris Risnandar</dc:creator><dc:creator>Imam Taufiqurrahman</dc:creator><dc:creator>Rizal Anshor</dc:creator><dc:creator>Miftahul Huda Pratama</dc:creator><dc:creator>Muhammad Lutfi Azhari</dc:creator><dc:subject>finite control set model predictive control</dc:subject><dc:subject>cascaded H-bridge inverter</dc:subject><dc:subject>seven-level inverter</dc:subject><dc:subject>multilevel converters</dc:subject><dc:subject>actuation delay</dc:subject><dc:subject>LCL filter</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>load imbalance</dc:subject><dc:subject>switching dynamics</dc:subject><dc:subject>discrete state-space model</dc:subject><dc:subject>voltage tracking</dc:subject><dc:subject>power factor correction</dc:subject><dc:description xml:lang="en">Multilevel cascaded H-bridge (CHB) inverters are widely used in power conversion systems because they can create high-quality voltage waveforms with low harmonic distortion. However, the predictive control of multilevel converters faces challenges such as computational delays, switching dynamics, and maintaining performance under nonideal conditions. This study explores finite-control-set model predictive control for a three-phase seven-level CHB inverter with an inductor capacitor inductor (LCL) filter, taking into account hardware-related imperfections. A discrete state-space model and a voltage-tracking cost function are used to assess 343 possible switching vectors at each sampling interval. Second-order reference extrapolation is applied to manage the typical one-sample actuation delay in real-time digital systems. Simulation results show that, in ideal conditions, the inverter achieves a voltage total harmonic distortion (THD) of less than 0.1% and a power factor close to one. Under realistic disturbances, such as dc-link voltage drops and load imbalances, the system remained stable, with the THD increasing slightly to approximately 5%. Thus, the controller maintains good waveform quality and dynamic stability despite common disturbances in converter operations and digital control limits. The main contribution is integrating second-order reference extrapolation within a hardware-aware finite-control-set model predictive control (FCS-MPC) framework, providing a practical basis for future real-time implementation and validation through processor-in-the-loop (PIL) or hardware-in-the-loop testing.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.11500</dc:identifier><dc:identifier>10.11591/eei.v15i5.11500</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 3895-3907</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11500/5048</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Andang, A., Risnandar, M. A., Taufiqurrahman, I., Anshor, R., Pratama, M. H., & Azhari, M. L. (2026). Finite-set MPC for a 7-level cascaded H-bridge simulation-based evaluation with reference extrapolation and non-idealities. Bulletin of Electrical Engineering and Informatics, 15(5), 3895–3907. https://doi.org/10.11591/eei.v15i5.11500
Salin
IEEE
A. Andang, M. A. Risnandar, I. Taufiqurrahman, R. Anshor, M. H. Pratama, and M. L. Azhari, “Finite-set MPC for a 7-level cascaded H-bridge simulation-based evaluation with reference extrapolation and non-idealities,” Bulletin of Electrical Engineering and Informatics, vol. 15, no. 5, pp. 3895–3907, 2026, doi: 10.11591/eei.v15i5.11500.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.