Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Signal quality assessment of surface electromyography envelope extraction across multiple noise conditions

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 4096–4106

DOI
10.11591/eei.v15i5.13937
ISSN
2089-3191, 2302-9285
Terbit
2026-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Envelope extraction is a fundamental preprocessing step in surface electromyography (sEMG) for myoelectric control, yet its signal quality under varying noise conditions remains insufficiently characterized using classification-independent metrics. This study assessed the signal quality of seven envelope extraction configurations, spanning instantaneous, static low-pass, and adaptive Kalman-based smoothing, using a dual-metric framework combining intrinsic signal-to-noise ratio (SNR) and power-reference correlation (p). Twenty subjects from the Ninapro DB2 dataset were examined under clean conditions and four noise types (power-line interference (PLI), motion artifact (MA), white Gaussian noise (WGN), and their combination), all scaled to 10 dB SNR. Static low-pass filtering achieved the highest intrinsic SNR (up to 4.4 dB), whereas the instantaneous tier attained the highest fidelity (p up to 0.985) but strongly negative SNR (-6 to -13 dB); the adaptive Kalman tier was intermediate (1.5-1.9 dB, p=0.87). Within the adaptive tier, a Hilbert-based front-end outperformed rectification under PLI (+0.43 dB), MA (+0.29 dB), and combined noise (+0.22 dB; all p

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 51 tautan kepenulisan bersama · 17 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Universitas Stikubank
  • University of Indonesia
  • State University of Semarang
  • Universitas Pendidikan Ganesha
  • State University of Medan
  • Duta Wacana Christian University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Edi WinarkoUniversitas Gadjah Mada3
Retantyo WardoyoUniversitas Gadjah Mada3
Sri T. HartatiUniversitas Gadjah Mada2
Edy WinarnoUniversitas Stikubank2
Aniati Murni ArymurthyUniversity of Indonesia2
Muhammad AuzanUniversitas Gadjah Mada2
Kridalaksana Harsa AwangAfiliasi tidak diketahui1
Zaenal AbidinState University of Semarang1
Yustina RetnoAfiliasi tidak diketahui1
Abriyono AbriyonoAfiliasi tidak diketahui1
I Gede Aris GunadiUniversitas Pendidikan Ganesha1
Rocky Yefrenes DillakUniversitas Gadjah Mada1
Ikhwan RusliantoUniversitas Gadjah Mada1
Rahmi HidayatiUniversitas Gadjah Mada1
Salman AliajiUniversitas Gadjah Mada1
Refta ListiaUniversitas Gadjah Mada1
Mahmuddin YunusAfiliasi tidak diketahui1
Hermawan SyahputraState University of Medan1
Sri SuwarnoDuta Wacana Christian University1
Rajif Agung YunmarSumatera Institute of Technology1
Nurmiyati TamatjitaUniversitas Gadjah Mada1
La Ode Hasnuddin S. SagalaUniversitas Gadjah Mada1
Nicodemus Mardanus SetiohardjoPoliteknik Negeri Kupang1
I Putu Adi PratamaUniversitas Gadjah Mada1
Herman HermanUniversitas Ahmad Dahlan1
Dian Hafidh ZulfikarUniversitas Gadjah Mada1
Made Leo RadhityaInstitut Bisnis dan Teknologi Indonesia1
Kharis SyabanUniversitas Gadjah Mada1
Pawit RiantoAfiliasi tidak diketahui1
Adri PriadanaUniversitas Gadjah Mada1
Ade NurhopipahUniversitas Amikom Purwokerto1
Aina MusdholifahUniversitas Gadjah Mada1
Nelson RumuiPoliteknik Negeri Ketapang1
Angga Maulana PurbaUniversitas Gadjah Mada1
Mohammad Edi WibowoAfiliasi tidak diketahui1
Silvano SugidamayatnoUniversitas Gadjah Mada1
Abdul KholikUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Signal quality assessment of surface electromyography envelope extraction across multiple noise conditions</dc:title><dc:creator>Catur Atmaji</dc:creator><dc:creator>Agus Harjoko</dc:creator><dc:creator>Danang Lelono</dc:creator><dc:subject>surface electromyography</dc:subject><dc:subject>envelope detection</dc:subject><dc:subject>signal quality assessment</dc:subject><dc:subject>noisy environments</dc:subject><dc:subject>power line interference</dc:subject><dc:subject>motion artifacts</dc:subject><dc:subject>Gaussian white noise</dc:subject><dc:subject>Kalman smoother</dc:subject><dc:subject>low-pass filtering</dc:subject><dc:subject>Hilbert transform</dc:subject><dc:subject>myoelectric control</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:description xml:lang="en">Envelope extraction is a fundamental preprocessing step in surface electromyography (sEMG) for myoelectric control, yet its signal quality under varying noise conditions remains insufficiently characterized using classification-independent metrics. This study assessed the signal quality of seven envelope extraction configurations, spanning instantaneous, static low-pass, and adaptive Kalman-based smoothing, using a dual-metric framework combining intrinsic signal-to-noise ratio (SNR) and power-reference correlation (p). Twenty subjects from the Ninapro DB2 dataset were examined under clean conditions and four noise types (power-line interference (PLI), motion artifact (MA), white Gaussian noise (WGN), and their combination), all scaled to 10 dB SNR. Static low-pass filtering achieved the highest intrinsic SNR (up to 4.4 dB), whereas the instantaneous tier attained the highest fidelity (p up to 0.985) but strongly negative SNR (-6 to -13 dB); the adaptive Kalman tier was intermediate (1.5-1.9 dB, p=0.87). Within the adaptive tier, a Hilbert-based front-end outperformed rectification under PLI (+0.43 dB), MA (+0.29 dB), and combined noise (+0.22 dB; all p</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.13937</dc:identifier><dc:identifier>10.11591/eei.v15i5.13937</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 4096-4106</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/13937/4990</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>