Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Development of a risk assessment tool for early detection of glaucoma based on machine learning methods

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 4653–4670

DOI
10.11591/eei.v15i5.11682
ISSN
2089-3191, 2302-9285
Terbit
2026-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Glaucoma is a progressive optic neuropathy and a major cause of irreversible blindness, making reliable early screening particularly important. This study proposes an automated glaucoma risk assessment framework based on color fundus photographs, combining a ResNet-50 classifier with cycle-consistent generative adversarial network (CycleGAN)-based synthetic data augmentation. The model was evaluated on the retinal image database for optic nerve evaluation for deep learning (RIM-ONE DL) dataset under limited and imbalanced data conditions. Training on real images alone resulted in an accuracy of 76.8%, recall of 74.2%, and area under the receiver operating characteristic curve (AUC-ROC) of 0.825. After adding 500 synthetic normal and 500 synthetic glaucoma images to the training set, accuracy increased to 91.4%, recall to 89.7%, and AUC-ROC to 0.943. Synthetic image quality was additionally evaluated using Fréchet inception distance (FID), kernel inception distance (KID), and learned perceptual image patch similarity (LPIPS) metrics and expert visual assessment. The results demonstrate that CycleGAN-based augmentation can substantially improve glaucoma classification performance under limited-data conditions while preserving clinically relevant retinal structures. The proposed approach may therefore serve as a supplementary decision-support tool for automated glaucoma screening.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Satbayev University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Development of a risk assessment tool for early detection of glaucoma based on machine learning methods</dc:title><dc:creator>Eduard Schiller</dc:creator><dc:creator>Sabina Rakhmetulayeva</dc:creator><dc:creator>Anastassiya Tyunina</dc:creator><dc:subject>glaucoma</dc:subject><dc:subject>glaucoma risk assessment</dc:subject><dc:subject>early detection</dc:subject><dc:subject>color fundus images</dc:subject><dc:subject>synthetic data augmentation</dc:subject><dc:subject>CycleGAN</dc:subject><dc:subject>ResNet50</dc:subject><dc:subject>class imbalance</dc:subject><dc:subject>automated glaucoma screening</dc:subject><dc:subject>decision support</dc:subject><dc:description xml:lang="en">Glaucoma is a progressive optic neuropathy and a major cause of irreversible blindness, making reliable early screening particularly important. This study proposes an automated glaucoma risk assessment framework based on color fundus photographs, combining a ResNet-50 classifier with cycle-consistent generative adversarial network (CycleGAN)-based synthetic data augmentation. The model was evaluated on the retinal image database for optic nerve evaluation for deep learning (RIM-ONE DL) dataset under limited and imbalanced data conditions. Training on real images alone resulted in an accuracy of 76.8%, recall of 74.2%, and area under the receiver operating characteristic curve (AUC-ROC) of 0.825. After adding 500 synthetic normal and 500 synthetic glaucoma images to the training set, accuracy increased to 91.4%, recall to 89.7%, and AUC-ROC to 0.943. Synthetic image quality was additionally evaluated using Fréchet inception distance (FID), kernel inception distance (KID), and learned perceptual image patch similarity (LPIPS) metrics and expert visual assessment. The results demonstrate that CycleGAN-based augmentation can substantially improve glaucoma classification performance under limited-data conditions while preserving clinically relevant retinal structures. The proposed approach may therefore serve as a supplementary decision-support tool for automated glaucoma screening.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.11682</dc:identifier><dc:identifier>10.11591/eei.v15i5.11682</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 4653-4670</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11682/5059</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>