Akses terbuka
Jurnal
SINTA 1
Efficient electrocardiogram signal coding for medical devices using linear prediction
Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 5 (2026) · hlm. 4734–4744
ISSN 2089-3191, 2302-9285
Terbit 2026-10-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
The growing adoption of wearable health monitoring and internet of things (IoT)-based medical devices has increased the demand for efficient electrocardiogram (ECG) compression techniques that reduce data size while preserving diagnostic fidelity. This paper proposes a compression method that combines linear predictive coding (LPC) with a residual thresholding mechanism. The ECG signal is modeled using a tenth-order LPC framework, and the residual is sparsified by retaining only the most significant components. The novelty of this work lies in applying threshold-based residual sparsification tailored to ECG signals, enabling high compression ratios (CR) while preserving clinically relevant waveform features. Experimental results using PhysioNet ECG data show that the proposed method achieves CRs of up to 38:1, while a moderate threshold (alpha is 0.005) provides a practical trade-off, achieving around 20:1 compression with preserved P wave, QRS complex, and T wave. The method offers a low-complexity solution suitable for wearable and IoT-based healthcare applications.
Jaringan kolaborasi para penulis
15 penulis ·
47 tautan kepenulisan bersama
· 20 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
German Jordanian University American University of the Middle East Hashemite University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Efficient electrocardiogram signal coding for medical devices using linear prediction</dc:title><dc:creator>Sameer Ahmad Hasan</dc:creator><dc:creator>Samer Alabed</dc:creator><dc:creator>Amer Alsaraira</dc:creator><dc:creator>Yasin Omar</dc:creator><dc:subject>ECG signal compression</dc:subject><dc:subject>linear predictive coding</dc:subject><dc:subject>compression ratio</dc:subject><dc:subject>wearable health monitoring</dc:subject><dc:subject>IoT medical devices</dc:subject><dc:subject>P wave</dc:subject><dc:subject>QRS complex</dc:subject><dc:subject>T wave</dc:subject><dc:subject>low-complexity compression</dc:subject><dc:description xml:lang="en">The growing adoption of wearable health monitoring and internet of things (IoT)-based medical devices has increased the demand for efficient electrocardiogram (ECG) compression techniques that reduce data size while preserving diagnostic fidelity. This paper proposes a compression method that combines linear predictive coding (LPC) with a residual thresholding mechanism. The ECG signal is modeled using a tenth-order LPC framework, and the residual is sparsified by retaining only the most significant components. The novelty of this work lies in applying threshold-based residual sparsification tailored to ECG signals, enabling high compression ratios (CR) while preserving clinically relevant waveform features. Experimental results using PhysioNet ECG data show that the proposed method achieves CRs of up to 38:1, while a moderate threshold (alpha is 0.005) provides a practical trade-off, achieving around 20:1 compression with preserved P wave, QRS complex, and T wave. The method offers a low-complexity solution suitable for wearable and IoT-based healthcare applications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i5.11688</dc:identifier><dc:identifier>10.11591/eei.v15i5.11688</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 5 (2026); 4734-4744</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11688/5045</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Hasan, S. A., Alabed, S., Alsaraira, A., & Omar, Y. (2026). Efficient electrocardiogram signal coding for medical devices using linear prediction. Bulletin of Electrical Engineering and Informatics, 15(5), 4734–4744. https://doi.org/10.11591/eei.v15i5.11688
Salin
IEEE
S. A. Hasan, S. Alabed, A. Alsaraira, and Y. Omar, “Efficient electrocardiogram signal coding for medical devices using linear prediction,” Bulletin of Electrical Engineering and Informatics, vol. 15, no. 5, pp. 4734–4744, 2026, doi: 10.11591/eei.v15i5.11688.
Salin