Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Enhancement of Ozonation Reaction for Efficient Removal of Phenol from Wastewater Using a Packed Bubble Column Reactor

Indonesian Journal of Chemistry · Vol. 23 No. 2 (2023) · hlm. 383–383

DOI
10.22146/ijc.78271
ISSN
1411-9420, 2460-1578
Terbit
2023-04-10
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

In the ozonation process, the phenol degradation in wastewater undergoes a low mass transfer mechanism. In this study, ozonized packed bubble column reactor was designed and constructed to remove phenol. The reactor’s inner diameter and height were 150 and 8 cm, respectively. The packing height was kept constant at 1 m in accordance with the reactor hydrodynamics. The gas distributor was designed with 55 holes of 0.5 mm. The phenol removal efficiency was evaluated at ozone concentrations of 10, 15, and 20 mg/L, contact times of 15, 30, 45, 60, 75, 90, 105, and 120 min, and phenol concentrations of 3, 6, 9, 12, and 15 mg/L. The results indicated that the highest phenol removal efficiency of 100% was achieved at 30 min in presence of packing. Moreover, the use of packing improved the contact between the gas and liquid, which significantly enhanced the phenol degradation. Actually, a thin film over a packing surface enhances the mass transfer. Also, it was found that the phenol is degraded into CO2 and H2O through a series of reaction steps. Additionally, a kinetic study of a first-order reaction provided an efficient estimation of reaction parameters with a correlation factor of 0.997.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 18 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology - Iraq
  • Northern Technical University
  • Al-Turath University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Noor Edin MousaUniversity of Technology - Iraq1
Seba S. MohammedNorthern Technical University1
Zainab Yousif ShnainUniversity of Technology - Iraq1
Mohammad Fadhil AbidAl-Turath University1
Asawer A. AlwasitiUniversity of Technology - Iraq1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Enhancement of Ozonation Reaction for Efficient Removal of Phenol from Wastewater Using a Packed Bubble Column Reactor</dc:title><dc:creator>Saja A. Alattar</dc:creator><dc:creator>Khalid A. Sukkar</dc:creator><dc:creator>May Ali Alsaffar</dc:creator><dc:subject>ozonation</dc:subject><dc:subject>phenol removal</dc:subject><dc:subject>wastewater treatment</dc:subject><dc:subject>mass transfer enhancement</dc:subject><dc:subject>gas-liquid contact</dc:subject><dc:subject>first-order kinetics</dc:subject><dc:subject>phenol degradation</dc:subject><dc:subject>ozone concentration</dc:subject><dc:subject>contact time</dc:subject><dc:description xml:lang="en">In the ozonation process, the phenol degradation in wastewater undergoes a low mass transfer mechanism. In this study, ozonized packed bubble column reactor was designed and constructed to remove phenol. The reactor’s inner diameter and height were 150 and 8 cm, respectively. The packing height was kept constant at 1 m in accordance with the reactor hydrodynamics. The gas distributor was designed with 55 holes of 0.5 mm. The phenol removal efficiency was evaluated at ozone concentrations of 10, 15, and 20 mg/L, contact times of 15, 30, 45, 60, 75, 90, 105, and 120 min, and phenol concentrations of 3, 6, 9, 12, and 15 mg/L. The results indicated that the highest phenol removal efficiency of 100% was achieved at 30 min in presence of packing. Moreover, the use of packing improved the contact between the gas and liquid, which significantly enhanced the phenol degradation. Actually, a thin film over a packing surface enhances the mass transfer. Also, it was found that the phenol is degraded into CO2 and H2O through a series of reaction steps. Additionally, a kinetic study of a first-order reaction provided an efficient estimation of reaction parameters with a correlation factor of 0.997.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-04-10</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.78271</dc:identifier><dc:identifier>10.22146/ijc.78271</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 2 (2023); 383-383</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/78271/36070</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>