Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Stability Study of Electrochemical Aptasensor to Detect SARS-CoV-2 Spike Protein and Its Application for Clinical Samples of Nasopharyngeal Swab

Indonesian Journal of Chemistry · Vol. 23 No. 2 (2023) · hlm. 370–370

DOI
10.22146/ijc.77887
ISSN
1411-9420, 2460-1578
Terbit
2023-03-03
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The stability characteristics associated with the shelf life of a biosensor are rarely investigated, however, they are important factors for real applications. Stability is the variation in the detection signal over a long period of storage. This study aims to determine the effect of storage time on the stability of SARS-CoV-2 receptor binding domain (RBD) spike protein aptamers related to shelf life and the performance of an electrochemical aptasensor on clinical samples. The research method includes a stability study conducted using the accelerated stability method based on the Arrhenius equation at three variations of temperature and storage time. The electrochemical aptasensor's performance was evaluated on clinical samples of 32 nasopharyngeal swabs at biosafety level 3 and its potential on clinical saliva samples. The results indicated that the developed electrochemical aptasensor was stable for ± 15 days with a shelf life of 18, 17 and 16 days, respectively, at 25, 40 and 50 °C. This electrochemical aptasensor has the potential to be a Point of Care (POC) device for the clinical detection of SARS-CoV-2 because it can be tested on clinical samples of nasopharyngeal swabs and the results show its potential application to detect in clinical saliva samples.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 138 tautan kepenulisan bersama · 18 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Padjadjaran University
  • Universitas Jenderal Achmad Yani
  • IPB University
  • Sekolah Tinggi Farmasi Indonesia
  • Universitas Garut
  • Keio University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Toto SubrotoPadjadjaran University11
Santhy WyantutiPadjadjaran University8
Iman Permana MaksumPadjadjaran University5
Ari HardiantoPadjadjaran University5
Umi BarorohSekolah Tinggi Farmasi Indonesia4
Sari SyahruniPadjadjaran University4
Tati HerlinaPadjadjaran University3
Ahmad Fariz MaulanaPadjadjaran University3
Husein Hernandi BahtiPadjadjaran University3
Uji PratomoPadjadjaran University3
Rahmaniar MulyaniPadjadjaran University3
Shinta KusumawardaniPadjadjaran University2
Riza AprianiUniversitas Garut2
Unang SupratmanPadjadjaran University2
Wanda DestiaraniPadjadjaran University2
Fauzian Giansyah RohmatullohPadjadjaran University2
Bachti AlisjahbanaPadjadjaran University2
Dewi AstrianySekolah Tinggi Farmasi Indonesia2
Cece SumantriIPB University2
Irma Isnafia AriefIPB University2
Cahyo BudimanIPB University2
Yasuaki EinagaKeio University2
Rustaman RustamanPadjadjaran University2
Nurlelasari NurlelasariPadjadjaran University2
Hesti Lina WiraswatiPadjadjaran University2
Anni AnggraeniPadjadjaran University1
Ratna Sari DewiPadjadjaran University1
Abdul MutholibPadjadjaran University1
Hesein H. BahtiPadjadjaran University1
Muhamad AbidinUniversitas Jenderal Achmad Yani1
Ashary Fathul HafidhUniversitas Jenderal Achmad Yani1
Mia WidyaningsihUniversitas Jenderal Achmad Yani1
Anceu MurniatiUniversitas Jenderal Achmad Yani1
Rima HandiyaniPadjadjaran University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Stability Study of Electrochemical Aptasensor to Detect SARS-CoV-2 Spike Protein and Its Application for Clinical Samples of Nasopharyngeal Swab</dc:title><dc:creator>Arum Kurnia Sari</dc:creator><dc:creator>Ghina Nur Fadhilah</dc:creator><dc:creator>Irkham Irkham</dc:creator><dc:creator>Muhammad Yusuf</dc:creator><dc:creator>Shabarni Gaffar</dc:creator><dc:creator>Yeni Wahyuni Hartati</dc:creator><dc:subject>electrochemical aptasensor</dc:subject><dc:subject>SARS-CoV-2</dc:subject><dc:subject>spike protein receptor-binding domain</dc:subject><dc:subject>aptamer stability</dc:subject><dc:subject>shelf life</dc:subject><dc:subject>accelerated stability testing</dc:subject><dc:subject>Arrhenius equation</dc:subject><dc:subject>nasopharyngeal swab</dc:subject><dc:subject>saliva detection</dc:subject><dc:subject>point-of-care testing</dc:subject><dc:subject>COVID-19 diagnosis</dc:subject><dc:description xml:lang="en">The stability characteristics associated with the shelf life of a biosensor are rarely investigated, however, they are important factors for real applications. Stability is the variation in the detection signal over a long period of storage. This study aims to determine the effect of storage time on the stability of SARS-CoV-2 receptor binding domain (RBD) spike protein aptamers related to shelf life and the performance of an electrochemical aptasensor on clinical samples. The research method includes a stability study conducted using the accelerated stability method based on the Arrhenius equation at three variations of temperature and storage time. The electrochemical aptasensor's performance was evaluated on clinical samples of 32 nasopharyngeal swabs at biosafety level 3 and its potential on clinical saliva samples. The results indicated that the developed electrochemical aptasensor was stable for ± 15 days with a shelf life of 18, 17 and 16 days, respectively, at 25, 40 and 50 °C. This electrochemical aptasensor has the potential to be a Point of Care (POC) device for the clinical detection of SARS-CoV-2 because it can be tested on clinical samples of nasopharyngeal swabs and the results show its potential application to detect in clinical saliva samples.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-03-03</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.77887</dc:identifier><dc:identifier>10.22146/ijc.77887</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 2 (2023); 370-370</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/77887/35925</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>