Akses terbuka
Jurnal
SINTA 1
A New Flow Injection System with Merging-Zone Technique for the Determination of Copper(II) by Neocuproine Reagent in Aqueous Solution
Indonesian Journal of Chemistry · Vol. 22 No. 1 (2022) · hlm. 770–770
ISSN 1411-9420, 2460-1578
Terbit 2022-04-26
Penerbit Gadjah Mada University
Bahasa en
Abstrak
A fast, simple, and high throughput sample merging-zone flow injection design was developed to determine copper(II) in aqueous solution. The procedure is based on the reduction of copper(II) to copper(I) by uric acid followed by a direct reaction with Neocuproine reagent (NC). The orange-yellow complex that forms absorb light at 454 nm. All conditions of the new flow injection unit were investigated. The analytical curve of copper(II) was linear with (r2) value of 0.9978, in the range of 0.4 to 40 mg/L with a detection limit of 0.1 mg/L and a quantification limit of 0.3 mg/L. the molar absorptivity was 1.661 × 105 L/mol cm and the recovery range was between 104.9 and 97%. The homemade acrylic valve was low-cost with zero dead volume and high repeatability (n = 7) with an RSD of 2.31%. The dispersion coefficient values were 1.8,1.62, and 1.31 for the concentrations of 5, 15, and 25 mg/L, respectively. The sample throughput was 69 h–1.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Babylon University of Anbar
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A New Flow Injection System with Merging-Zone Technique for the Determination of Copper(II) by Neocuproine Reagent in Aqueous Solution</dc:title><dc:creator>Ahmed Saleh Farhood</dc:creator><dc:creator>Dakhil Nassir Taha</dc:creator><dc:subject>copper(II) determination</dc:subject><dc:subject>flow injection analysis</dc:subject><dc:subject>neocuproine</dc:subject><dc:subject>uric acid lowering</dc:subject><dc:subject>copper(I) complexes</dc:subject><dc:subject>aqueous solution analysis</dc:subject><dc:subject>high-throughput analysis</dc:subject><dc:description xml:lang="en">A fast, simple, and high throughput sample merging-zone flow injection design was developed to determine copper(II) in aqueous solution. The procedure is based on the reduction of copper(II) to copper(I) by uric acid followed by a direct reaction with Neocuproine reagent (NC). The orange-yellow complex that forms absorb light at 454 nm. All conditions of the new flow injection unit were investigated. The analytical curve of copper(II) was linear with (r2) value of 0.9978, in the range of 0.4 to 40 mg/L with a detection limit of 0.1 mg/L and a quantification limit of 0.3 mg/L. the molar absorptivity was 1.661 × 105 L/mol cm and the recovery range was between 104.9 and 97%. The homemade acrylic valve was low-cost with zero dead volume and high repeatability (n = 7) with an RSD of 2.31%. The dispersion coefficient values were 1.8,1.62, and 1.31 for the concentrations of 5, 15, and 25 mg/L, respectively. The sample throughput was 69 h–1.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2022-04-26</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.70799</dc:identifier><dc:identifier>10.22146/ijc.70799</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 22 No 1 (2022); 770-770</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/70799/33607</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
10 sitasi
Crossref
Terindeks
lewat DOI
5 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Farhood, A. S., & Taha, D. N. (2022). A New Flow Injection System with Merging-Zone Technique for the Determination of Copper(II) by Neocuproine Reagent in Aqueous Solution. Indonesian Journal of Chemistry, 22(1), 770–770. https://doi.org/10.22146/ijc.70799
Salin
IEEE
A. S. Farhood and D. N. Taha, “A New Flow Injection System with Merging-Zone Technique for the Determination of Copper(II) by Neocuproine Reagent in Aqueous Solution,” Indonesian Journal of Chemistry, vol. 22, no. 1, pp. 770–770, 2022, doi: 10.22146/ijc.70799.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.