Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Chromatographic and Spectrophotometric Determination of Clindamycin in Pharmaceutical Products

Indonesian Journal of Chemistry · Vol. 24 No. 3 (2024) · hlm. 845–845

DOI
10.22146/ijc.91599
ISSN
1411-9420, 2460-1578
Terbit
2024-06-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Accurate, precise, and reliable chromatographic and spectrophotometric methods were developed for determining clindamycin (CLD) in pharmaceutical formulations. The spectrophotometric method was adopted for flow injection analysis (FIA). The method is based on the online oxidation of CLD and measuring the absorbance of the resulting product using a flow cell at 605 nm. Experimental conditions, including FIA variables and reaction conditions, were optimized. The chromatographic separation was achieved using a C8 column and an isocratic mobile phase. The composition of the mobile phase selected for the analysis consists of a mixture of phosphate buffer (50%), MeOH (35%), and ACN (15%), adjusted to a pH of 3.47 by phosphoric acid. The eluent was monitored with a UV detector at 205 nm. The linearity range was 10–200 and 50–800 µg/mL for the FIA and HPLC, respectively. The applicability of the FIA and HPLC methods was validated by analyzing CLD in synthetic and commercial pharmaceutical products. No significant interferences were observed from the common excipients usually used in commercial formulations.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Al al-Bayt University
  • Yarmouk University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
“Ayat Allah” Al‐MassaedhAl al-Bayt University2
Asmaa Ali Al-SerhanAl al-Bayt University1
Ahmed Al-SarhanAl al-Bayt University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Chromatographic and Spectrophotometric Determination of Clindamycin in Pharmaceutical Products</dc:title><dc:creator>Idrees Faleh Al-Momani</dc:creator><dc:creator>Lana Mohammad Zaid Al-Kilani</dc:creator><dc:subject>clindamycin</dc:subject><dc:subject>flow injection analysis</dc:subject><dc:subject>HPLC</dc:subject><dc:subject>spectrophotometric determination</dc:subject><dc:subject>drug formulation</dc:subject><dc:subject>pharmaceutical analysis</dc:subject><dc:subject>method validation</dc:subject><dc:subject>excipient interference</dc:subject><dc:description xml:lang="en">Accurate, precise, and reliable chromatographic and spectrophotometric methods were developed for determining clindamycin (CLD) in pharmaceutical formulations. The spectrophotometric method was adopted for flow injection analysis (FIA). The method is based on the online oxidation of CLD and measuring the absorbance of the resulting product using a flow cell at 605 nm. Experimental conditions, including FIA variables and reaction conditions, were optimized. The chromatographic separation was achieved using a C8 column and an isocratic mobile phase. The composition of the mobile phase selected for the analysis consists of a mixture of phosphate buffer (50%), MeOH (35%), and ACN (15%), adjusted to a pH of 3.47 by phosphoric acid. The eluent was monitored with a UV detector at 205 nm. The linearity range was 10–200 and 50–800 µg/mL for the FIA and HPLC, respectively. The applicability of the FIA and HPLC methods was validated by analyzing CLD in synthetic and commercial pharmaceutical products. No significant interferences were observed from the common excipients usually used in commercial formulations.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.91599</dc:identifier><dc:identifier>10.22146/ijc.91599</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 3 (2024); 845-845</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/91599/38829</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>